Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Left
Below
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.0010531113
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Rear
right
Right
more than 10cm
more than 10cm
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
Attention must be paid to
the rising up of drain hose
G
more than 10cm
F
A
C
D
E
more than15cm
Selection of Installation Place
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor fixing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.
loading

Sommaire des Matières pour Haier HSU-09HEA103

  • Page 13: Préparation

    Manuel d'installation d'un climatiseur de pièce Préparation Outillage requis pour l'installation Sélection de l'emplacement pour l'installation Unité intérieure Clé Clé dynamométrique (17 mm, 22 mm, 26 mm) Pince ● L'emplacement doit être solide sans vibration et offrir un support suffisant. ●...
  • Page 14: Accessoires

    [Gauche • Tuyauterie arrière gauche] Accessoires Dans le cas d'une tuyauterie à gauche, découpez, avec une pince, le couvercle pour la tuyauterie gauche. Pour une tuyauterie à l'arrière gauche, cintrez les tuyaux selon le sens de la tuyau- Télécommande (1) Tuyau de vidange (1) terie jusqu'à...
  • Page 15: Unité Extérieure

    Hauteur max: Amax=10m Unité extérieure Si la hauteur A dépasse les 5m, HSU-12HEA03 /R2 HSU-12HEA03 /R2-I installez un piège à huile tous les HSU-09RH03/R2 HSU-09HEA103/R2 Piège dl'huile 5 à 7 m HSU-12RH03/R2 HSU-12HEA103/R2 Longueur max: Bmax=15m Unité intérieure Si la longueur du tuyau B dépasse les 7 m, le réfrigérant doit être...
  • Page 16: Etiquette De Charge De Réfrigérant

    Matrice de l'outillage 3. Mettez sous vide pendant plus de 15 min. Vérifiez également le manomètre qui doit 1.Coupez le tuyau d'évasement 2. Nettoyez les ébavures indiquer -0.1MPa (76 cm Hg) sur le côté basse pression. Après avoir effectué le vide, fermez la poignée Lo dans le collecteur à...