ANNEX 3: Installation of the Cyble sensor / Installation du module Cyble / Installation des Cyble-Sensor / Installa-
zione del Cyble Sensor / Instalación del módulo Cyble / Installatie van de Cyble Sensor / Cyble Sensor Montaji /
Instalação do Sensor Cyble / A Cyble szenzor telepítése
1) Mounting
ANNEX 4: Transmitters / Emetteurs / Impulsgeber / Emettitori di impulsi / Emisores / Pulsgever / Vericiler / Trans-
missores / Jeladók
Unless on the nameplate noted the following electrical parameters shall be considered:
Characteristics
Power rating
Voltage (Break-down)
Current (Switching)
Capacitance and Inductance
Operation temperature range
** Following recommend values Low Frequency Pulse Transmitters do not have any potential sources of ignition and shall
be not marked according to directive 2014/34/EU.
The device is free to be used in ATEX area as it is a simple apparatus as defined in EN 60079-11 §5.7.
*** Proximity detectors conform to EN60947-5-6 (NAMUR) standard.
Characteristics
Contact power rating
Voltage (Break-down)
Current (Switching)
Operation temperature range
Plugging of the meter (extern view of the socket installed on the meter)
50
2) Screwing (Max torque: 0,25Nm)
Low Frequency Transmitter (reed contact)
For Non ATEX
products
Max. 10 W
Max. 180 V dc
Max. 50 mA
C=0F, L=0H
-30°C to +60°C
LF, MF
DIN45326
For ATEX products **
intrinsically safe circuits
EN 60079-0/-11
Max. 120 mW
Max. 15 V dc
Max. 50 mA
C=0F, L=0H
-30°C to +60°C
Low Frequency Transmitter (Cyble Module)
Max. 1 W
Max. 14.3 V dc
Max. 50 mA
-25°C to +55°C
3) Sealing
High & Medium Frequency
Transmitter (inductive)
For ATEX products ***
intrinsically safe circuits EN
60079-0/-11
Max. 64 mW
Max. 15 V dc
Max. 50 mA
C=90nF, L = 250 µH
-30°C to +60°C
HF