Télécharger Imprimer la page

Robert Juliat 1459 FLO Consignes D'utilisation page 10

Publicité

A
d
Make sure the fan is working correctly
when switching on the unit.
Mains voltage.
- Check the conformity of the power supply unit C .
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lighting unit's power cable B by passing it
inside the yoke.
- Leave a little slack and then block the cable B into the lock d .
- Place the lamp into position - refer to section A - 9.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet and trapdoors
when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when the lamp is in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
All manuals and user guides at all-guides.com
TECHNICAL FILE
1800W MSR FOLLOWSPOTS
CONNECTIONS.
B
C
C
3
7
6
4
2
5
DESCRIPTION.
A
1800W Hot restrike followspot.
B
Lighting unit's power cable.
Cable 18G 1,5mm
, length 3m equipped
2
with 16 x 16A male HARTING connector.
C
Power supply unit.
1 - EF HARTING 16 x 16A - 2 latch connector.
2 - Mains cable socket.
3 - Time meter.
4 - General 16A circuit breaker (E.C).
- General 15A circuit breaker (UL/CSA).
5 - 5 x 20 Fuse holder (2A 250V).
6 - Mains, checklight.
7 - "ON/OFF" switch.
8 - Lamp ON, checklight.
If the lamp's checklight is OFF when the switch is
ON, the lighting of the lamp has failed.
Repeat the operation - refer to section A - 9.
9 & 10 - Rating plate.
FLO
Section A - 5
8
9
10
1
Power supply unit
(P.S.U.)

Publicité

loading

Ce manuel est également adapté pour: