TECHNICAL DATA
MODEL
OUTPUT
(1)
DELIVERY
(1)
FUEL
Gas pressure at maximum delivery
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
MAIN ELECTRICAL SUPPLY
CONTROL CIRCUIT POWER SUPPLY
FAN MOTOR
PUMP MOTOR
Capacitor
IGNITION TRANSFORMER
PUMP
delivery (at 12 bar)
pressure range
fuel temperatur
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
CONFORMITY TO EEC DIRECTIVES
NOISE LEVELS
(3)
Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(1)
Pressure at test point 18)(A)p.8 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)
ACCESSORIES
(optional):
KIT FOR LENGTHNING THE COMBUSTION HEAD
L = Standard length
L1 = Lenght obtainable with the kit
COD. 3010345
L = 250 mm
COD. 3010346
L = 250 mm
COD. 3010347
L = 250 mm
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 28.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
All the installation, maintenance and disassembly operations must be carried out with the electricity supply disconnected.
The burner requires periodic maintenance carried out by a qualified and authorised technician in conformity with legislation and local
standards.
2nd stage
kW
kg/h
min. 1st stage
kW
kg/h
Gas: G20/G25/G31
mbar
(2)
number
°C
°C max
Ph/V/Hz
Ph/V/Hz
rpm
V
Hz
W
A
rpm
V
Hz
W
A
µF
V1 - V2
I1 - I2
kg/h
bar
° C max
W max
dBA
L1 = 385 mm
L1 = 385 mm
L1 = 385 mm
RLS 70
465 - 814
39 - 69
232
19
LIGHT OIL. viscosity at 20 °C: 6 mm
NATURAL GAS: G20 (methane) - G21 - G22 - G23 - G25
GPL - G30 (propane) - G31 (butane)
6.2/7.5/7.8
- Intermittent (min. 1 stop in 24 hours)
- Two-stage (high and low flame) and single-stage (all - nothing)
2
Boilers: water. steam. diathermic oil
3/220-380/60
3475
220/380
60
1100
4,2/2,4
230 V - 2 x 5 kV
1,9 A - 30 mA
2000
2006/42 - 2004/108 - 2006/95
74
• RLS 70
• RLS 100
• RLS 130
6
RLS 100
RLS 130
698 - 1163
930 - 1395
59 - 98
78 - 118
349
465
29.5
39
2
/s max (1.5 °E - 6 cSt)
10/13/12
11.5/14.4/15
0 - 40
60
1N/220/60
3500
3500
220/380
220/380
60
60
2200
2200
8,1/4,7
8,1/4,7
3300
220
60
550
4,6
16
220
10 - 20
60
2700
3200
IP 44
77,5
80