6 Accessories
A wide range of accessories is available
for your KL 2500 LCD. A separate bro-
chure gives you comprehensive
information – to get it see addresses
overleaf.
Only Schott light guides and accesso-
ries guarantee perfect operation, safety
and optimum light yield.
6.1 Light guides
Self-supporting and flexible light gui-
des in various lengths and diameters
are available, as well as point and slit
illuminators.
6.2 Halogen lamps
When ordering halogen lamps as spare
parts (see point 6.6 of this instruction),
the lamp type that enables optimum
light yield and illumination will be sup-
plied.
6.3 Filters
Optical filters can either be inserted
into the filter wheel (7) or placed in
front of the light guide exit as a screw-
in or push-on filter in conjunction with
an auxiliary focussing device (acces-
sory). Details of the auxiliary focussing
device and the filter types available as
standard can be found in the accesso-
ries catalogue.
19
All manuals and user guides at all-guides.com
6.4 Remote control
The following functions can be control-
led by remote control:
• Light on/off ("STAND-BY")
• Electronic light intensity adjustment
6.6 Spare parts
Spare part
Halogen lamp 24 V/250 W
Osram, type HLX 64653
Philips, type 13163
Fuse for 230 V (primary)
T 3,15 H, 250 V acc. to IEC 127-3/5
Fuse for 120 V (primary)
M 6,3 A acc. to UL 198 G
To ensure maximum performance, light yield and safety you must only use the
spare parts stated above.
7 Technical data
Properties
General information
Type description
Dimensions (W x D x H)
Weight
Cooling
Ambient temperature*
Relative air humidity*
Air pressure*
Transport and storage
Temperature
Rel. air humidity
Air pressure
Contamination level
* Test conditions of Standards DIN EN 61010-1, DIN EN 60601-1 and UL 3101-1.
6.5 Inclination angle switch
The inclination angle switch switches
the light source into the "Light on"
or "STAND-BY" modes depending on
its angle of inclination relative to the
ground. Inclination angle switches are
mounted, for example, on the freely
mobile arm of diagnosis microscopes.
Both the remote control and the
inclination angle switch have a con-
nection cable 3 m long as standard.
A cable splitter enables a remote con-
trol and inclination angle switch to be
operated simultaneously. Please consult
the instructions enclosed with the res-
pective device for detailed information
on the remote control and inclination
angle switch.
Catalogue No.
253 000
253 101
253 103
Values
-
KL 2500 LCD
mm
approx. 200 x 265 x 170
kg
approx. 6
-
axial (fan cooled)
°C
+ 5 ... + 40
%
at 31°C ambient temperature: 85 %
from 31°C to 40°C ambient temperature:
decreasing linearly to 75 %
hPa
700 ... 1060
°C
- 40 ... + 70
%
10 ... 95 (non-condensing)
hPa
500 ... 1200
-
2