Télécharger Imprimer la page

Heath Zenith DUAL BRITE SL-5597 Installation page 3

Masquer les pouces Voir aussi pour DUAL BRITE SL-5597:

Publicité

Les langues disponibles

Les langues disponibles

TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on or when switching modes wait 1
Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the
TEST position.
Bottom of Sensor
Avoid aiming the sensor at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting
light may trigger the shut-off feature. Do not point
other lights at the sensor.
8 ft.
(2.4 m)
70 ft.
100 ft.
(21 m) (30.5 m)
Boosted
Maximum
Range
The control is most sensitive to motion across it.
Motion
Sensor
Least Sensitive
595-5679-05
All manuals and user guides at all-guides.com
1
/
minute warm up period
2
1
/
minutes.
2
240°
Maximum
Coverage Angle
Motion
Most Sensitive
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sen-
sor at least 2" (51 mm) away
from the lamps.
Adjust the RANGE as needed.
Too much range may increase
false triggering. Range Boost
increases coverage up to
100 feet.
Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).
Set the DUAL BRITE™ switch to the amount of
time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m); 100
Sensing Angle . . . . . . . . Up to 240°
Electrical Load . . . . . . . . 200 watt Incandescent (100
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . . 1 , 5, 20 minutes
Dual Brite™ Timer . . . . . 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . . T4 100W, G8 halogen bi-pin
Heath
®
/Zenith reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
Page 3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
ft.(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Max each lamp holder.)
MODE
120 VAC

Publicité

loading