Connect the Wiring
Risk of electric shock. Electrical wiring must be done by qualifi ed
personnel in accordance with all applicable codes and standards.
Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power from being switched
on accidentally.
1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw.
2 ] Reinstall the blowers cover plate using both lock nuts and 10 screws previously removed in
step 4 on page 10. Pay attention to screw 1 and screw 8 location; from back of hood point of
view, screw 8 must be located on left side of the lock nut and screw 1 must be located on
right side of the lock nut (see insets).
A
3 ] Reinstall the decorative panel to the hood by hanging it back on its 3 hooks (A), then tilt it
until it reaches the 3 magnets on blowers cover (B).
!
WARNING
HOUSE
POWER CABLE
5
6
9
7
8
10
8
LOCK NUTS
MOTORS
GROUND
WIRE
GROUND
SCREW
4
3
2
1
BACK OF HOOD
1
B
MAGNETS