Position For Outdoor Unit; Tubing Selection; Indoor Unit Installation; Outdoor Unit Installation - GIA Pure Light UV HTWS026PLUV Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The all figures are only schematic, and they may be slightly different from the actual
appliances you selected.

Position for Outdoor Unit

Avoid direct sunlight.
Away from heat source, steam source, leakage of flammable gas, smoke and dust.
Select a place that is away from rain (snow) and has good ventilation.
Neighbors will not be affected by the blown wind and noise, or discharged water.
The place that is easy to install and service.
Mounted on the solid and reliable foundation will not increase noise or shock.
To get high cooling performance, make sure the unit's front, rear, left and right sides
must be located in an open area.
The outlet is proposed to be in open air, any obstacle will affect the performances.
The installing distance must be required as Fig. 2 shows.

Tubing Selection

Ensure that the level (height) difference of indoor and outdoor units and the length of tu-
bing meet the requirement In the Table 1.
If the tubing is longer than 7m, but shorter than 15m, refrigerant should be supplemented
according to Table 1.
Outdoor unit
Indoor unit
Height
difference
Table 1
At l east
15cm
Fig.2
Indoor unit
26
At least 10cm
At l east
40cm
At least 2m
Outdoor unit
Fig.3

Publicité

Table des Matières
loading

Table des Matières