3.2 Osmotic membrane replacement
- Run water from the tap over the sink to reduce circuit pressure.
- Disconnect the connection pipe on the RO VESSEL top.
- Unscrew the RO VESSEL top.
- With a clamp, remove the membrane.
- Insert a new membrane.
- Screw in the RO VESSEL top.
- Insert the connection pipes.
WARNING
At re-start after every maintenance operation and/or refill change, when the unit's bowl is unscrewed from head, change the o-ring with a new one and carefully lubricate
with original lubricant Lubrikit+ before tightening the bowl to the head. Make sure that there are no water leaks from the product, and especially control the tightening be-
tween the housing head and the housing bowl. Continue checking that the tightening is good and there is no water leakage for 48 hours following the Installation and start-
up. In case of leakage, open the housing, remove the o-ring from the bowl, place a new o-ring and apply original lubricant Lubrikit+, then re-tighten the bowl to head and
repeat the leakage check as above. Use only original Atlas Filtri o-rings otherwise the warranty is void. Ask your Vendor for original o-rings, Lubrikit+ and other spare parts.
Remark: after the maintenance, slowly turn on a water supply (tap) downstream the installed unit and let the water flow for at least 10/15 minutes before the use.
3.3 Filter cartridge replacement
Original cartridges are available in a practical and convenient KITS.
OASIS SANIC models - OASIS SANIC cartridge KIT
1. SEDIMENT - String wound SANIC filter 5 micron
2. SEDIMENT - PP melt blown SANIC filter 5 micron.
3. VOC Volatile-Organic-Compound carbon block filter 5 micron
The average filter cartridge working life varies according to use, environmental conditions, pressure, etc. In general, changes in water taste, odour and colour indicate that
the cartridge requires replacement.
A. Before opening the container, turn off water supply tap and place a container under the system to collect any water that may spill when the cartridges are removed.
B. Release product pressure by opening a downstream tap.
C. Open the filter housing by unscrewing the bowl from the top.
D. Remove the used cartridge.
E. Gently clean the bowl with cold water and a soft sponge.
F. Remove the protective film from the new cartridge.
G. Insert the new cartridge in the bowl.
H. Lubricate the bowl o-ring with the lubricant included in the package (Lubrikit+). If the o-ring appears damaged, replace it with a new o-ring (o-ring included in the
package) and lubricate with Lubrikit+.
I. Screw the bowl onto the head and tighten with a wrench, do not over tighten.
J. Slowly open the main water tap.
K. Let water flow for about 5 minutes from a tap downstream from the product before use. This also allows air purge of the product.
Using cartridges other than original ones voids the warranty.
WARNING
At re-start after every maintenance operation and/or refill change, when the unit's bowl is unscrewed from head, change the o-ring with a new one and carefully lubricate
with original lubricant Lubrikit+ before tightening the bowl to the head. Make sure that there are no water leaks from the product, and especially control the tightening be-
tween the housing head and the housing bowl. Continue checking that the tightening is good and there is no water leakage for 48 hours following the Installation and start-
up. In case of leakage, open the housing, remove the o-ring from the bowl, place a new o-ring and apply original lubricant Lubrikit+, then re-tighten the bowl to head and
repeat the leakage check as above. Use only original Atlas Filtri o-rings otherwise the warranty is void. Ask your Vendor for original o-rings, Lubrikit+ and other spare parts.
Remark: after the maintenance, slowly turn on a water supply (tap) downstream the installed unit and let the water flow for at
least 5 minutes before the use.
3.4 AIC activated carbon post-filter replacement
- Remove the blue safety rings from the post-filter quick-fits (input and output).
- Press the quick-fits coupling release ring to remove the input and output pipes.
- Unscrew the quick fit system and screw it back onto the new cartridge applying the adequate amount of PTFE tape
- Extract the used post-filter from the bracket and replace it with a new AIC post-filter (only use original spare parts or the warranty is voided).
- Fit the pipes in the input and output, making sure the pipes are securely locked in the quick-fit.
- Re-insert the safety rings in the quick-fits.
3.5 AIM re-mineralising post-filter replacement
Perform the replacement steps as in the procedure described in point 3.4.
4. NON-ROUTINE MAINTENANCE
Non-routine maintenance (repairs and/or replacement of non consumable parts) must be performed by personnel qualified by the manufacturer and accredited distributors,
or the warranty is void.