Potential equali-
zation
Assembling the
charging module
Fit two feet to the uprights
Fit a crossbeam between each upright
WARNING! An electric shock can be deadly. If, for reasons of plant technology,
equipotential bonding of the charging module is necessary, it must be installed at
a suitable location (for example, existing holes). Proper execution is system-spe-
cific and is the responsibility of the installer!
45
SW17
8x
M10 x 25
8x
8x
SW15
8x
8x
8x
SW13
SW13
M8 x 20
2x
25
9