Installation Instructions – Luminaire WaveStream
Instructions d'installation - Luminaire WaveStream
Instrucciones de instalación de la luminaria WaveStream
IMPORTANT: Read carefully before installing fixture.
Retain for future reference.
WARNING
Risk of fire, electrical shock, cuts and or other casualty
hazards. This product must be installed in accordance
with the applicable installation code by a qualified
electrician or a person familiar with the construction
and operation of the product and the hazards involved.
Cooper Lighting assumes no responsibility for claims
brought about by improper or careless installation or
handling of this product.
ATTENTION
Receiving Department: Note actual fixture description
of any shortage or noticeable damage on delivery
receipt. File claim for common carrier (LTL) directly
with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material,
complete with original packing must be retained.
CAUTION
Edges May Cut. Handle with care.
INSTALLATION
Fixture Installation/Wiring
1.
Remove product from packaging material. Carton
should be lying down flat, oriented with THIS SIDE UP
markings facing up so that top panel of carton can be
folded back and fixture can be lifted straight up out of
packaging materials. Do not lift fixture by one end or
pull on the end plates in any way. Luminaire should be
handled by both aluminum side rails. Wear clean work
gloves to prevent dirt and oil from being transferred to
luminaire.
2.
Note that the protective plastic insert that is shipped
in the luminaire is intended to stay in the luminaire for
protection of the lenses during installation (Figure1.).
Take caution when handling the luminaire to not
scratch or damage the lenses inthe fixture.
CAUTION
Risk of burn. Disconnect power and allow fixture to cool
before changing bulb or handling fixture.
WARNING
Risk of Fire and Electric Shock. If not qualified, consult
an electrician.
NOTICE
Green ground screw provided in proper location. Do not
relocate.
NOTICE
If supply wires are located within 3 inches of ballast, use
wire rated for at least 90°C (194°F).
CAUTION
Risk of Electric Shock. The light source contained in this
luminaire shall only be replaced by the manufacturer or his
service agent or a similar qualified person.
Figure 1.
Brand Logo
reversed out of
black
INS #
INS #
Plastic Insert

Publicité

loading

Sommaire des Matières pour Eaton Metalux ADF140666

  • Page 1 Brand Logo reversed out of black INS # INS # ADF140666 Installation Instructions – Luminaire WaveStream Instructions d’installation - Luminaire WaveStream Instrucciones de instalación de la luminaria WaveStream CAUTION IMPORTANT: Read carefully before installing fixture. Retain for future reference. Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
  • Page 2 BLACK OR BROWN = LINE 1 BLUE = LED – LOAD BLUE OR ORANGE = LINE 2 WHITE OR BLUE = NEUTRAL GRN OR GRN/YLW = GROUND STEP DIM DRIVER Wiring Diagrams Installation Instructions – Luminaire WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 3 Due to the non-contact and solvent-free nature of this cleaning method, it should be used as a first step in cleaning all optics. Installation Instructions – Luminaire WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 4 à grille en T (Figure 3). Prenez soin de ne pas Figure 2. Installez dans le système à grille en T au plafond. trop serrer et décaper les vis. Instructions d’installation - Luminaire WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 5: Installation Du Câble

    GRIS = DALI ROUGE = DEL + NOIR OU MARRON = LIGNE 1 CHARGE BLEU = DEL - BLEU OU ORANGE = LIGNE 2 BLANC OU BLEU = NEUTRE VERT OU VERT/JAUNE = TERRE PILOTE Schémas de câblage Instructions d’installation - Luminaire WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 6: Entretien

    à angle rasant sur la surface optique dans un sens unique constant. Comme cette méthode ne requiert aucun contact et aucun solvant, elle doit être le premier recours pour le nettoyage de toute surface optique. Instructions d’installation - Luminaire WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 7 Asegúrese de que todas las luminarias de una cierta Compartimiento área estén orientadas en la misma dirección. de conexiones eléctricas Figure 2. Instalar en sistema de vigas en T del techo Instrucciones de instalación de la luminaria WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 8: Diagramas De Cableado

    AZUL O NARANJA = LÍNEA 2 BLANCO O AZUL = NEUTRO VERD. O VERD./AMAR. = CONEXIÓN A TIERRA CONTROLADOR DE REGULACIÓN POR ETAPAS Diagramas de cableado Gancho EQ instalado Figure 3. Instrucciones de instalación de la luminaria WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 9 óptica de manera unidireccional y constante. Debido a que este método de limpieza carece de solventes y no utiliza contacto, debe utilizarse como primer paso en la limpieza de todas las lentes ópticas. Instrucciones de instalación de la luminaria WaveStream 0590AWSIS ADF140666 www.eaton.com...
  • Page 12 All trademarks are property 1121 Highway 74 South of their respective owners. Peachtree City, GA 30269 www.eaton.com/lighting Eaton est une marque de commerce déposée. Toutes les autres marques © 2017 Eaton de commerce sont la propriété de leur All Rights Reserved propriétaire respectif.