Télécharger Imprimer la page

Titan IMPACT 1140IA Manuel D'entretien page 11

Avec intellisync et activguard

Publicité

Les langues disponibles

Les langues disponibles

1140I / 1140IA
2.6
REPLACING THE FILTERS
PUMP FILTER
1.
Loosen and remove the filter body
by hand.
2.
Slip the filter off of the core spring.
3.
Inspect the filter.
inspection, clean or replace the
filter.
4.
Inspect the o-ring.
inspection, clean or replace the
o-ring.
5.
Slide the new or cleaned filter
over the core spring with the filter
spring adapter in place. Push the
filter into the center of the filter
housing.
6.
Slide the filter body over the filter
and thread it into the filter housing
until secure.
The filter housing
i
should be hand-
tightened, but
make sure the filter
housing is seated
fully into the pump
block.
GUN FILTER
1.
Unclip the top of the trigger guard from the gun body.
2.
Using the bottom of the trigger guard as a wrench, loosen and
remove the handle assembly from the gun head.
3.
Pull the old filter out of the gun body. Clean or replace.
4.
Slide the new filter, tapered end first, into the gun head.
5.
Thread the handle assembly into the gun head. Tighten with the
trigger wrench.
6.
Snap the trigger guard back onto the gun body.
For more detail, part number information, and
i
complete assembly drawings, please see the RX-
Pro Airless Gun Owner's Manual.
Filter Body
Based on
Filter Spring
Based on
Filter
Filter Spring
Adapter
Core Spring
O-ring
Filter Housing
Gun
Body
Filter
Handle
MAINTENANCE
11

Publicité

loading

Ce manuel est également adapté pour:

Impact 114024192942419291