In case of difficulty
PROBLEM
Thermostat's
housing is hot.
Wrong
temperature is
displayed.
Display
disappears and
reappears after a
few minutes.
LO is displayed
HI is displayed
E1, E2 is
displayed
This is normal. When the thermostat is running at full capacity, its
housing can reach 40 °C (104 °F).
Rectify if any of the following conditions applies:
The thermostat is exposed to air draft.
The sticker on the thermostat's screen has not been removed.
The thermostat is located near or above a heat source such as
a light dimmer.
The thermal protection device on the heater has temporarily
opened. This can happen if the heater is obstructed by furniture
or curtain and has overheated, or if the heater's thermal
protection device is too sensitive.
The measured temperature is below the display range. Heating is
activated.
The measured temperature is above the display range.
The thermostat performance is reduced due to a sensor error.
Please contact technical support for more information.
SOLUTIONS
11
69-2793EF—05