Télécharger Imprimer la page

Beurer medical BM 58 Mode D'emploi page 25

Masquer les pouces Voir aussi pour BM 58:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
ing on something. Do not cross your legs. Place your feet
flat on the ground.
• In order not to distort the result, it is important to keep still
during the measurement and not talk.
Measuring blood pressure
• Move the touch screen activation switch to the ON position.
• Put on the cuff as described previously and assume the
position in which you want to carry out the measurement.
• Switch on the blood pressure monitor with the START/
STOP button
. After the full-screen display, the most
recently used user memory appears (
the user memory, press the MEM button and confirm
your selection with the START/STOP button
ton is pressed, the most recently used user memory is
automatically used after 5 seconds.
• Before the measurement, the last saved test result is
briefly displayed. If there is no measurement in the mem-
ory, the instrument always displays the value .
• The cuff automatically inflates. Cuff air pressure is
released slowly. If a tendency towards high blood pres-
sure is already detectable, the cuff is pumped up again
and cuff pressure increased further. As soon as a heart
rate is detected, the heart rate symbol
• Heart rate, systolic and diastolic blood pressure are dis-
played.
• You can cancel the measurement at any time by press-
• The test result is saved automatically.
• To switch off the device, press the START/STOP button
or
). To change
Wait at least 5 minutes before taking another measurement!
. If no but-
6. Evaluating results
Cardiac arrhythmia:
This instrument can identify possible cardiac arrhythmia dis-
orders during measurement and if necessary indicates the
measurement with the flashing icon
This may be an indicator for arrhythmia. Arrhythmia is a
condition where the heart rhythm is abnormal as a result of
defects in the bioelectrical system controlling the heart beat.
The symptoms (omitted or premature heart beats, slow or
is displayed.
excessively fast heart rate) may be caused, among other
things, by heart disease, age, physical predisposition, exces-
25
ing the START/STOP button
screen activation button to OFF.
_ appears if it has not been possible to perform the
measurement properly. Observe the section in these
instructions on error messages/troubleshooting and
repeat the measurement.
or push the touch screen activation switch to OFF. If
you forget to switch off the device, it switches off auto-
matically after approx. 1 minute.
or by pushing the touch
.

Publicité

loading