C. Make sure your tools or appliances on in the off position, and then you may plug them
in the socket.
If connected equipment is in the ON position before connecting, it will start suddenly, and cause injury or damage.
D. Turn on equipment.
If the generator is overloaded or if there is a malfunction in your equipment, green output indicator light will turn off and the red
overload indicator light will turn on and power output from the generator will not continue. If this occurs the engine will not stop, you
must turn off the ignition switch to stop engine in order to reset the power circuit of the generator.
If the equipment power requirement meets the system capability for initial start-up, the overload indicator and output indicator
will turn on at the same time for a short period, that's normal.
The red indicator light will turn off and the green light stays on after
the equipments start.
2. How to Use 12 Volt DC Output
When using the DC output, turn the Auto Idle switch to the OFF position (see diagram #56361 for switch location)
You can use DC power and AC power at the same time.
DC overload circuit may disconnect, reset circuit protector by pressing reset button.