NATURAL GAS MODELS:
These installation instructions MUST be used in conjunction with the Vector™ installation manual.
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
ADD MANUAL TITLE
INSTALLATION MANUAL
Dynamic Heat Control™
INTERTEK
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
ADD PRODUCT IMAGE
air outlet opening
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
FOR USE WITH VECTOR™ MODELS ONLY
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
(Installation Option 2 illustrated)
FOR INDOOR USE ONLY
FOR INDOOR USE ONLY
NUMBER LABEL HERE
LV38N/P-1 / LV38N/P2-1 / LV50N/P-2 / LV50N/P2-2 /
LV62N/P / LV62N/P2 / LV74N/P / LV74N/P2
IF SEPARATE MANUALS, ADD "PLACE
(STANDARD ON ALL LUXURIA™ MODELS)
W415-2373 / B / 04.30.21
ENGLISH
FRENCH PG. 31

Publicité

loading

Sommaire des Matières pour Napoleon Dynamic Heat Control

  • Page 1 (STANDARD ON ALL LUXURIA™ MODELS) BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com W415-2373 / B / 04.30.21...
  • Page 2 12.0 maximum protrusion 13.0 Dynamic Heat Control™ installation checklist note: The information throughout this manual is believed to be correct at the time of printing. Wolf Steel Ltd. reserves the right to change or modify any information within this manual at any time without notice.
  • Page 3 Ability to place a TV, sound bar or artwork above the fi replace. The Dynamic Heat Control™ system relies on an optimized fl ow of air both through the appliance and the enclosure. As such the installation of the Dynamic Heat Control™ system requires certain technical considerations when com- pared to traditional fi...
  • Page 4 WARNING • Do NOT cover or place any items in the Dynamic Heat Control™ air outlet. Failure to comply with these instructions will create a fi re hazard. ir fl ow within the air passage is not restricted in any way with the exception of approved venting.
  • Page 5 Installation Option 1 (open enclosure) leaves a complete air outlet opening above the enclosure to provide the necessary air circulation path for the Dynamic Heat Control™ system. This has been found to be well accepted with respect to fi nal appearance and offer minimal distraction. It also allows for effi cient circulation of air within the room.
  • Page 6 It will also allow the air to circulate more effectively in the room. However, if the appliance is equipped with the Dynamic Heat Control™ Plus, then the opening size must be 80 sq. in. for models LV38-1, LV50-2, LVX38(-1), and LVX50(-1), or 160 sq.
  • Page 7 For Dynamic Heat Control™ Plus, a second opening MUST NOT be installed.
  • Page 8 installation planning 3.0 appliance overview SINGLE-SIDED INSTALLATION fi xed side access side pilot location defl ectors shown after installation top view front frame (frame and defl ectors not shown) WARNING: DO NOT REMOVE access FROM FIXED SIDE side For knockout plate removal (access side only), see “Dynamic Heat access side side view...
  • Page 9 Dynamic Heat Control™ installation 4.0 Dynamic Heat Control™ installation Before starting the Dynamic Heat Control™ installation, remove the safety barrier. Refer to “safety barrier installation/removal” section in the appliance installation manual. SINGLE-SIDED MODEL ILLUSTRATED Front Frame 1.) Remove fasteners securing front frame (and rear 2.) Remove knockouts plates (FOR SINGLE-SIDED, ONLY REMOVE...
  • Page 10 Dynamic Heat Control™ installation FOR LV50-2 / LV74 4.) Bend the sides of the defl ectors as shown. 5.) Remove outer knockout fasteners. Do not discard fasteners. FOR LV38-1 / LV62 5.) Secure defl ectors to the appliance with supplied fasteners as 6.) Secure defl...
  • Page 11 Dynamic Heat Control™ installation high limit switch installation WARNING • High Limit Switch installation is MANDATORY. Failure to correctly install will cause a fi re hazard. Bracket Install Location access side Wire Harness Control Board Plug with spade connectors Wire Harness “X4”...
  • Page 12 Secure high limit switch assembly with a supplied screw as shown. IMPORTANT: After installing the Dynamic Heat Control™ system, ensure appliance is clean from dust, debris, etc. before continuing with the appliance installation. Take precautions to ensure framing or fi...
  • Page 13 Dynamic Heat Control™ installation 5.0 minimum framing dimensions note: When using optional fi nishing accessories, the framing dimensions and fi nishing materials may differ from what is out- lined in the section below; refer to the leafl et instructions supplied in the accessory kit for specifi c framing and fi nishing specifi...
  • Page 14 minimum clearance to combustible enclosures 6.0 minimum clearance to combustible enclosures single-sided 1” [25mm] minimum all sides for sections 6” [152mm] minimum of vertical venting. (inside enclosure) When passing through 3” [76mm] top (outside a ceiling, use fi restop of enclosure) spacer W500-0028 (not supplied) 2”...
  • Page 15 minimum clearance to combustible enclosures see-thru 6” [152mm] minimum 1” [25mm] minimum all sides for (inside enclosure) sections of vertical venting. When passing 3” [76mm] top (out- through a side of enclosure) ceiling, use 2” [51mm] sides / fi restop spacer bottom (outside of W500-0028 (not enclosure)
  • Page 16 fi nish framing - after appliance installation 7.0 rough framing - before appliance installation Before framing your appliance, determine vent requirements before deciding the fi nal location of the appliance. After rough framing, place the appliance in its fi nal position. Also, see appliance manual for vent shield installation, nailing tabs installation,electrical installation, gas installation, etc.
  • Page 17 8.0 fi nish framing - after appliance installation fi nish framing - after appliance installation There are various methods to ventilate the enclosure. Refer to “installation planning” section. Only one option is illustrated (Installation Option 2 - front opening). The appliance must be installed at this point of framing. Appliance is not shown to better illustrate framing. single-sided fl...
  • Page 18 fi nish framing - after appliance installation single-sided recessed WARNING • Shaded components (fi nish framing) must be non-combustible materials. Ceiling note: Finish framing must be built after appliance has been placed in its fi nal position and venting connected. This confi...
  • Page 19 fi nish framing - after appliance installation see-thru fl ush Ceiling note: Finish framing must be built after appliance has been placed in its fi nal position and venting connected. Drywall Installation Option 2 illustrated (appliance not shown) Insulation minimum framing LV38-1 LV50-2 LV62...
  • Page 20 fi nish framing - after appliance installation see-thru built out Drywall note: Finish framing must be built after appliance has been placed in its fi nal position and venting connected. Insulation Installation Option 2 illustrated (appliance not shown) minimum framing LV38-1 LV50-2 LV62...
  • Page 21 fi nish framing - after appliance installation wiring locations TV applications were tested with the minimum enclosure dimensions and the maximum recess permissible. This data is provided in good faith and is not a guarantee for every application and television. Care and consideration should be taken when planning these installations to ensure the temperatures around the TV meet all manufacturer’s recommended operating temperatures.
  • Page 22 fi nish framing - after appliance installation 9.0 fastener placement restriction WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi...
  • Page 23 fi nish framing - after appliance installation 10.0 fi nishing With Dynamic Heat Control™, you can fi nish the appliance with any combustible materials except ap- pliances with recessed installation. Air outlet opening must be located out of reach of the user. Air outlet pening must not be restricted by furnishings or decor.
  • Page 24 fi nish framing - after appliance installation 10.1 enclosure design Additional openings in the enclosure are not acceptable since the DHC™ system relies on the “chimney effect” created through the appliance and the enclosure. By adding additional air inlet(s) to an enclosure, air can bypass the appliance, which increases the operating temperature of the appliance and around the appliance opening.
  • Page 25 fi nish framing - after appliance installation 10.2 optional trim fi nishing When the appliance is installed with the front (or rear) air outlet opening, a decorative trim kit is available to fi nish your installation. The trim kit can be painted as an accent colour or to blend in with room decor. The minimum air opening area must be maintained after the fi...
  • Page 26 fi nish framing - after appliance installation 11.0 minimum combustible mantel clearances WARNING • Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 27 fi nish framing - after appliance installation 12.0 maximum protrusion WARNING • Finishing material tight to the frame around the fi nshing fl ange must not project more than 4” (38mm) from the face of the safety barrier (above the door and sides only). SIDE VIEW 4"...
  • Page 28 fi nish framing - after appliance installation 13.0 Dynamic Heat Control™ installation checklist SINGLE-SIDED WARNING • Ensure knockout plates on the fi xed side are not removed or damaged (single-sided only). Front frame installed 2 knockout plates removed (Access side only) defl...
  • Page 29 notes W415-2373 / B / 04.30.21...
  • Page 30 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, The Netherlands Phone: 1-866-820-8686 napoleon.com...
  • Page 31 BARCODE LABEL ON THE OWNER’S MANUAL” (STANDARD AVEC TOUS LES MODÈLES LUXURIA Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com W415-2373 / B / 04.30.21...
  • Page 32 12.0 saillie maximale 13.0 liste complète de vérification de l’installation Dynamic Heat Control note: L’information contenue dans ce manuel est jugée correcte au moment de l’impression. Wolf Steel Ltée. se réserve le droite de modifi er ou de modifi er toute information contenue dans ce manuel à...
  • Page 33 Possibilité de placer un téléviseur, une barre de son ou une œuvre d’art au-dessus du foyer sans aucun risque d’endommagement. Le système Dynamic Heat Control dépend d’une circulation d’air améliorée passant par l’appareil et l’enceinte. En outre, l’installation du système exige certaines considérations techniques par rapport aux foyers traditionnels. Plus précisément, il nécessite que l’enceinte soit bien ventilée et que l’installateur s’assure qu’une zone d’ouverture minimale...
  • Page 34 2.0 planifi cation de l’installation AVERTISSEMENT • NE COUVREZ OU PLACEZ PAS aucune d’objets dans l’ouverture de sortie d’air de Dynamic Heat Control Le non-respect de ces instructions pourrait créer un risque d’incendie. • Assurez-vous que le débit d’air dans la zone de l’enceinte n’est pas restreint d’aucune façon à l’exception de l’évacuation approuvée.
  • Page 35 Option d’Installation n° 1 (enceinte ouverte) laisse une ouverture de sortie d’air complète au dessus de l’enceinte afi n de fournir la chemin de circulation d’air nécessaire pour le système Dynamic Heat Control . Cela a été trouvé d’être bien accepté quant à...
  • Page 36 3 - ouverture arrière CONVIENT pour Dynamic Heat Control Plus Option d’Installation n° 3 (ouverture arrière) requiert une ouverture de sortie d’air d’être encadré pas plus de 1,5” au dessous du haut de l’enceinte afi n d’éviter de piéger la chaleur dans les zones plus hautes et l’ouverture de sortie d’air centrée sur le centre de l’appareil.
  • Page 37 à des hauteurs différentes qui répondent aux paramètres d’installation à des fi ns esthétiques. Pour Dynamic Heat Control Plus, une deuxième ouverture NE DOIT PAS être installée.
  • Page 38 3.0 vue d’ensemble de l’appareil SEUL CÔTÉ côté fi xé emplacement côté d’accès du pilote défl ecteurs montrées vue de dessus après l’installation cadre avant (cadre et défl ecteurs non illustrés) AVERTISSEMENT: NE RE- côté TIREZ PAS DE CÔTÉ FIXÉ. d’accès Pour le retrait de la plaque knockout (côté...
  • Page 39 Dynamic Heat Control™ installation 4.0 installation de Dynamic Heat Control Avant de commencer l’installation du système Dynamic Heat Control , retirez la barrière de protection. Voir la section « installation /enlèvement de la barrière de protection » dans le manuel d’installation de l’appareil.
  • Page 40 Dynamic Heat Control POUR LV50-2 / LV74 4.) Pliez les côtés des défl ecteurs comme illustré. 5.) Retirez les vis extérieures du knockout. Ne jetez pas les vis. POUR LV38-1 / LV62 5.) Fixez les défl ecteurs à l’appareil avec les vis fournies comme 6.) Fixez les défl...
  • Page 41 Dynamic Heat Control installation de l’interrupteur de surchauffe AVERTISSEMENT • L’installation de l’interrupteur de surchauffe est OBLIGATOIRE. Le défaut d’installer correctement l’interrupteur de surchauffe peut entraîner un risque d’incendie. Emplacement de l’Installation du Support côté d’accès Harnais de Fils Panneau de Contrôle...
  • Page 42 Fixez l’assemblage de l’interrupteur de surchauffe avec une vis fournie comme illustré. IMPORTANT: Après avoir installé le système Dynamic Heat Control , assurez-vous que l’appareil est propre à partir de poussières, de débris, etc. avant de continuer à l’installation de l’appareil. Prenez des précautions pour assurer que la poussière ou le débris de l’encadrement ou des fi...
  • Page 43 5.0 dimensions d’ossature minimaux installation de Dynamic Heat Control note: Lorsque vous utilisez des accessoires de fi nition optionnels, les dimensions d’ossature et les matériaux de fi nitions peuvent différer de ce qui est décrit dans la section ci-dessous. Reportez-vous aux instructions du feuillet fourni dans le kit d’acccessoire pour des spécifi...
  • Page 44 minimum clearance to combustible enclosures 6.0 dégagements minimaux aux enceintes combustibles seul côté 1” [25mm] minimum tous côtés pour 6” [152mm] minimum l’évacuation verticale. (dans l’enceinte) En passant par un 3” [76mm] en haut (à plafond, utilisez coupe- l’extérieur de l’enceinte) feu W500-0028 (non fourni) 2”...
  • Page 45 dégagements minimaux aux enceintes combustibles voir à travers 6” [152mm] minimum 1” [25mm] minimum tous cô- (dans l’enceinte) tés pour l’évacuation verticale. 3” [76mm] en haut (à En passant par un l’extérieur de l’enceinte) plafond, utilisez coupe- 2” [51mm] côtés / bas (à...
  • Page 46 fi nish framing - after appliance installation 7.0 ossature approximatif - avant l’installation de l’appareil Avant d’encadrer votre appareil, déterminez les exigences d’évent avant de décider l’emplacement fi nal de l’appareil. Après l’ossature approximatif, placez l’appareil dans son emplacement fi nal. Aussi, voir le manuel d’appareil pour l’installation du bouclier d’évent, l’installation des onglets de clous, l’installation électrique, l’installation de gaz, etc.
  • Page 47 8.0 ossature fi ni - après l’installation de l’appareil fi nish framing - after appliance installation Il y a différentes méthodes de ventiler l’enceinte. Voir la section « planifi cation de l’installation ». Seulement un option est illustré (Option d’Installation n° 2 - ouverture avant). L’appareil doit être installé...
  • Page 48 ossature fi ni - après l'installation de l'appareil seul côté encastré AVERTISSEMENT • Les components ombragés (ossature fi ni) doit être des matériaux incombustibles. Plafond note: L’ossature fi ni doit être construit après l’appareil a été placés dans son position fi nale et ventilation a été...
  • Page 49 ossature fi ni - après l'installation de l'appareil voir à travers fl ush Plafond note: L’ossature fi ni doit être construit après l’appareil a été placés dans son position fi nale et ventilation a été connecté. Cloison Sèche Option d’Installation n° 2 illustré (appareil non illustré).
  • Page 50 ossature fi ni - après l'installation de l'appareil voir à travers construit à l’extérieur Cloison Sèche note: L’ossature fi ni doit être con- struit après l’appareil a été placés dans son position fi nale et ventilation a été connecté. Option d’Installation n° 2 illustré Isolant (appareil non illustré).
  • Page 51 ossature fi ni - après l'installation de l'appareil endroits de câblage Les applications avec un téléviseur ont été testés avec les dimensions d’enceinte minimaux et l’encastré maximum permissible. Les données sont fournis de bonne foi et ne constituent pas une garantie pour chaque application et téléviseur.
  • Page 52 ossature fi ni - après l'installation de l'appareil 9.0 restriction d’emplacement des vis AVERTISSEMENT • Risque d’incendie! • N’obstruez jamais l’ouverture sur le devant de l’appareil. • La façade de l’appareil doit être faite de matériaux incombustibles comme de la brique, du marbre, du granite, etc., à...
  • Page 53 L’ouverture ne doit pas être obstruée par le mobilier ou la décoration. Ouverture de sor- tie d’air Dynamic Heat Control Installation encastré avec Dynamic Heat Control AVERTISSEMENT • La zone ombragée doit être les matériaux incombustibles. LA ZONE OMBRAGÉE DOIT ÊTRE LES MATÉ- RIAUX INCOMBUSTIBLES.
  • Page 54 ossature fi ni - après l'installation de l'appareil 10.1 conception de l’enceinte Les ouvertures supplémentaires ne sont pas autorisées parce-que le système DHC repose sur « l’effet de cheminée » crée avec l’appareil et l’enceinte. En ajoutant les ouvertures supplémentaires à l’enceinte, l’air peut éviter l’appareil, ce qui augmente la température d’opération de l’appareil et autour de l’ouverture de l’appareil.
  • Page 55 ossature fi ni - après l'installation de l'appareil 10.2 fi nition de la garniture optionnelle Lorsque l’appareil est installé avec une ouverture de sortie d’air à l’avant (ou à l’arrière), un ensemble de garniture décorative est disponible de fi nir votre installation. L’ensemble de garniture peut être peint comme une couleur d’accent ou de fondre dans la couleur du décor de la pièce.
  • Page 56 11.0 dégagements minimaux aux tablettes combustibles ossature fi ni - après l'installation de l'appareil AVERTISSEMENT • Risque d’incendie. Maintenir tous les espaces spécifi és pour les espaces combustibles. Le non-respect de ces instructions peut provoquer un incendie ou provoquer une surchauffe de l’appareil. Assurez-vous que tous les dégagements (c.à.d.
  • Page 57 ossature fi ni - après l'installation de l'appareil 12.0 saillie maximale AVERTISSEMENT • Les matériaux de fi nitions proches de l’ossature autour de la bride de fi nition ne doivent pas dépasser plus que 4” (38mm) de la face de la barrière de protection (au dessus de la porte et les côtés seulement). VUE DE CÔTÉ...
  • Page 58 13.0 liste complète de vérifi cation de l’installation Dynamic Heat Control SEUL CÔTÉ AVERTISSEMENT • Assurez-vous que les plaques knockout sur le côté fi xé ne sont pas enlévés ou endommagés (seul côté seulement). Cadre avant installé 2 plaques knockout retirés (côté...
  • Page 59 notes W415-2373 / B / 04.30.21...
  • Page 60 T IO ODUITS CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 De Riemsdijk 22, 4004 LC Tiel, Pays-Bas Téléphone: 1-866-820-8686...