NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
All manuals and user guides at all-guides.com
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
ADD MANUAL TITLE
INSTALLATION MANUAL
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CSA /
INTERTEK
LOGO
PRODUCT NAME™
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
FOR INDOOR USE ONLY
ENGLISH
FRENCH PG. 27
W415-1739 / C / 08.03.17

Publicité

loading

Sommaire des Matières pour Napoleon DYNAMIC HEAT CONTROL LVX38

  • Page 1 Retain this manual for future reference CSA / INTERTEK LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleonfi replaces.com • hearth@napoleonproducts.com $10.00 W415-1739 / C / 08.03.17...
  • Page 2 All manuals and user guides at all-guides.com table of contents general information installation planning installation option 1 - open enclosure (enclosure stops short of the ceiling) installation option 2 - front opening installation option 3 - rear opening installation option 4 - open enclosure with hard combustible valance appliance overview Dynamic Heat Control™...
  • Page 3 All manuals and user guides at all-guides.com 1.0 general information general information WARNING • Dynamic Heat Control™ MUST be installed during the installation of the appliance BEFORE appliance venting and gas are installed. • Ensure the appliance is completely cool before starting installation. •...
  • Page 4 All manuals and user guides at all-guides.com 2.0 installation planning installation planning WARNING • Do NOT cover or place any items in the Dynamic Heat Control™ air outlet. Failure to comply with these instructions will create a fire hazard. ir flow within the air passage is not restricted in any way with the exception of approved venting. •...
  • Page 5 All manuals and user guides at all-guides.com installation planning installation option 1 - open enclosure (enclosure stops short of the ceiling) NOT Suitable for Dynamic Heat Control™ Plus It is one option not to finish or close in the top of the enclosure to provide the necessary air circulation path for the Dynamic Heat Control™...
  • Page 6 All manuals and user guides at all-guides.com installation planning installation option 3 - rear opening Suitable for Dynamic Heat Control™ Plus Minimum air outlet opening dimension must be followed. The opening is required to be framed no more than 1.5” below the enclosure top (see option 3 diagram) to avoid trapping heat in the upper areas and centered on the appliance center.
  • Page 7 All manuals and user guides at all-guides.com installation planning note: See-thru appliances require front or rear air outlet opening. If desired, it can be installed with both front and rear air outlet openings to allow heat to circulate in two rooms however it is recommended to install the air outlet opening at different heights that meet the installation parameters for aesthetic purposes.
  • Page 8 All manuals and user guides at all-guides.com installation planning 3.0 appliance overview SINGLE-SIDED INSTALLATION fixed side access side pilot location deflectors shown after installation top view front frame (frame and deflectors not shown) WARNING: DO NOT REMOVE access FROM FIXED SIDE side For knockout plate removal (access side only), see “DHC...
  • Page 9 All manuals and user guides at all-guides.com Dynamic Heat Control™ installation 4.0 Dynamic Heat Control™ installation Before starting the Dynamic Heat Control™ installation, remove safety barrier. Refer to “safety barrier installation/ removal” section in the installation manual SINGLE-SIDED SHOWN Front Frame 1.) Remove fasteners securing front frame (and rear 2.) Remove knockouts plates (FOR SINGLE-SIDED, ONLY REMOVE frame for see-thru).
  • Page 10 All manuals and user guides at all-guides.com Dynamic Heat Control™ installation FOR LV50-2 / LV74 4.) Bend the sides of the deflectors as shown. 5.) Remove outer knockout fasteners. Do not discard fasteners. FOR LV38-1 / LV62 5.) Secure deflectors to the appliance with supplied fasteners as 6.) Secure deflectors to the appliance with fasteners removed in shown.
  • Page 11 All manuals and user guides at all-guides.com Dynamic Heat Control™ installation high limit switch installation WARNING • High Limit Switch installation is MANDATORY. Failure to correctly install will cause a fire hazard. Bracket Install Location access side Wire Harness Control Board Plug with spade connectors Wire Harness...
  • Page 12 All manuals and user guides at all-guides.com Dynamic Heat Control™ installation 4.) Locate the existing wire harness in the upper left corner 3.) Insert the high limit switch into the bracket and secure of the firebox as shown. Connect wires to the high limit with two fasteners (supplied).
  • Page 13 All manuals and user guides at all-guides.com Dynamic Heat Control™ installation 5.0 minimum framing dimensions note: When using optional finishing accessories, the framing dimensions and finishing materials may differ from what is out- lined in the section below; refer to the leaflet instructions supplied in the accessory kit for specific framing and finishing specifications.
  • Page 14 All manuals and user guides at all-guides.com minimum clearance to combustible enclosures 6.0 minimum clearance to combustible enclosures single-sided 1” [25mm] minimum to sides for vertical venting. 6” [152mm] minimum When passing through a ceiling, use firestop 3” [76mm] to top spacer W500-0028 (not supplied) 2”...
  • Page 15 All manuals and user guides at all-guides.com minimum clearance to combustible enclosures see-thru 1” [25mm] minimum to sides for vertical 6” [152mm] minimum venting. When passing through a 3” [76mm] to top ceiling, use 2” [51mm] to sides / firestop spacer bottom W500-0028 (not When passing through...
  • Page 16 All manuals and user guides at all-guides.com 7.0 rough framing - before appliance installation finish framing - after appliance installation Before framing your appliance, determine vent requirements before deciding the final location of the appliance. After rough framing, place the appliance in its final position. Also, see appliance manual for vent shield installation, nailing tabs installation,electrical installation, gas installation, etc.
  • Page 17 All manuals and user guides at all-guides.com 8.0 finish framing - after appliance installation finish framing - after appliance installation note: Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after framing.
  • Page 18 All manuals and user guides at all-guides.com finish framing - after appliance installation single-sided recessed WARNING • Shaded components (finish framing) must be non-combustible materials. Ceiling note: Finish framing must be built after appliance has been placed in its final position and venting con- nected.
  • Page 19 All manuals and user guides at all-guides.com finish framing - after appliance installation see-thru flush Ceiling note: Finish framing must be built after appliance has been placed in its final position and venting connected. Although the minimum enclosure height for the LV series is 73”, some venting configurations Drywall that require more vertical rise...
  • Page 20 All manuals and user guides at all-guides.com finish framing - after appliance installation see-thru built out Drywall note: Finish framing must be built Insulation after appliance has been placed in its final position and venting connected. Option 2 illustrated (appliance not shown) minimum framing LV38-1...
  • Page 21 All manuals and user guides at all-guides.com finish framing - after appliance installation 9.0 fastener placement restriction 2” 1 1/2” 6” 8” No fasteners permitted. No fasteners permitted with greater than 3/4” penetration into appliance. When securing non-combustibles, we suggest using high temperature construction adhesive within 2” (5.08cm) above and to the sides from the appliance opening and 8”...
  • Page 22 All manuals and user guides at all-guides.com finish framing - after appliance installation 10.0 finishing With Dynamic Heat Control™, you can finish the appliance with any combustible materials except ap- pliances with recessed installation. Air outlet opening must be located out of reach of the user. Air outlet pening must not be restricted by furnishings or decor.
  • Page 23 All manuals and user guides at all-guides.com finish framing - after appliance installation 11.0 minimum combustible mantel clearances WARNING • Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these instructions may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 24 All manuals and user guides at all-guides.com 12.0 maximum protrusion finish framing - after appliance installation WARNING • Finishing material tight to the frame around the finshing flange must not project more than 4” (38mm) from the face of the glass barrier (above the door and sides only). 4"...
  • Page 25 All manuals and user guides at all-guides.com finish framing - after appliance installation 13.0 completed DHC installation checklist SINGLE-SIDED WARNING • Ensure knockout plates on the fixed side are not removed or damaged (single-sided only). Front frame installed 2 knockout plates removed (Access side only) deflectors 2 cover plates removed...
  • Page 26 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686...
  • Page 27 Conservez ce manuel pour consultation ultérieure CSA / INTERTEK LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleonfoyers.com • hearth@napoleonproducts.com $10.00 W415-1739 / C / 08.03.17...
  • Page 28 All manuals and user guides at all-guides.com table des matières information générales planification de l’installation Option d’installation 1 - Enceinte ouverte (l’enceinte s’arrête du plafond) Option d’installation 2 - Ouverture avant Option d’installation 3 - Ouverture arrière option d’installation 4 - enceinte ouverte avec calcaire combustible dur vue d’ensemble de l’appareil installation Dynamic Heat Control™...
  • Page 29 All manuals and user guides at all-guides.com 1.0 information générales information générales AVERTISSEMENT • Dynamic Heat Control™ DOIT être installé pendant l’installation de l’appareil AVANT que l’évacuation de l’appareil et le gaz sont installés. • Assurez-vous que l’appareil est complètement frais avant de commencer l’installation. •...
  • Page 30 All manuals and user guides at all-guides.com planification de l'installation 2.0 planification de l’installation AVERTISSEMENT • NE PAS couvrir ou placer d’objets dans les ouvertures de ventilation. Cela permettra à l’appareil de fonctionner de manière incorrecte et peut causer un risque d’incendie. •...
  • Page 31 All manuals and user guides at all-guides.com planification de l'installation Option d’installation 1 - Enceinte ouverte (l’enceinte s’arrête du plafond) NON Convient pour Dynamic Heat Control™ Plus Il est une option de ne pas finir ou fermer dans le haut de l’enceinte pour fournir le chemin de circulation d’air nécessaire pour le système Dynamic Heat Control™.
  • Page 32 All manuals and user guides at all-guides.com planification de l'installation Option d’installation 3 - Ouverture arrière Suitable for Dynamic Heat Control™ Plus La dimension minimale d’ouverture de sortie d’air doit être suivie. L’ouverture doit être encadrée à plus de 1,5 “en dessous du sommet de l’enceinte (voir le diagramme de l’option 3) pour éviter de piéger la chaleur dans les zones supérieures et centrée sur le centre de l’appareil.
  • Page 33 All manuals and user guides at all-guides.com planification de l'installation note: Les appareils à commande électrique nécessitent une ouverture de sortie d’air avant ou arrière. Si vous le souhaitez, il peut être in- stallé avec des ouvertures de sortie d’air avant et arrière, mais il est recommandé d’installer à des hauteurs différentes qui répondent aux paramètres d’installation à...
  • Page 34 All manuals and user guides at all-guides.com planification de l'installation 3.0 vue d’ensemble de l’appareil SEUL CÔTÉ côté fixe Emplacement du côté accès pilote déflecteurs montrées après vue de dessus l’installation (Cadre et déflecteurs non représentés) Cadre avant AVERTISSEMENT: NE PAS RETIRER DE COTE FIXE côté...
  • Page 35 All manuals and user guides at all-guides.com installation Dynamic Heat Control™ 4.0 installation Dynamic Heat Control™ Avant de commencer l’installation Dynamic Heat Control™, retirez la barrière de sécurité. Reportez-vous à la section “Installation / retrait de la barrière de sécurité” dans le manuel d’installation UN CÔTÉ...
  • Page 36 All manuals and user guides at all-guides.com installation Dynamic Heat Control™ POUR LV50-2 / LV74 Pliez les côtés des volets de mise à l’air libre, comme indiqué. 5.) Enlevez les attaches extérieures des plaques poinçonnées. Ne jetez pas les attaches. POUR LV38-1 / LV62 5.) Fixez les volets de mise à...
  • Page 37 All manuals and user guides at all-guides.com installation Dynamic Heat Control™ installation de l’interrupteur de surchauffe AVERTISSEMENT • L’installation de l’interrupteur de limite supérieure est obligatoire. Le défaut d’installation correcte entraînera un risque d’incendie. Emplacement d’installation du support côté d’accès Faisceau de câbles Panneau de contrôle Bouchon avec...
  • Page 38 All manuals and user guides at all-guides.com installation Dynamic Heat Control™ 4.) Localisez le faisceau de câbles dans le coin supérieur 3.) Insérez l’interrupteur de surchauffe dans son support et gauche de la chambre de combustion, comme indiqué. fixez-le avec les deux attaches fournies. Connectez les fils au limiteur de course élevé.
  • Page 39 All manuals and user guides at all-guides.com installation Dynamic Heat Control™ 5.0 dimensions d’encadrement minimales note: Lorsque vous utilisez des accessoires de finition optionnels, les dimensions d’encadrement et les matériaux de finition peuvent différer de ce qui est décrit dans la section ci-dessous; Reportez-vous aux instructions de la brochure fournies dans le kit d’accessoires pour des spécifications spécifiques de cadrage et de finition.
  • Page 40 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 6.0 dégagements minimaux de l’enceinte single-sided 1” [25mm] minimum sur les côtés pour l’évacuation verticale. 6” [152mm] minimum En passant par un plafond, utilisez 3” [76mm] en haut l’intercalaire coupe- 2”...
  • Page 41 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte see-thru 1” [25mm] minimum sur les côtés pour l’évacuation verti- 6” [152mm] minimum cale. En passant par un plafond, utili- 3” [76mm] en haut sez l’intercalaire 2” [51mm] Aux côtés / coupe-feu W500-0028 (non En passant par un...
  • Page 42 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 7.0 encadrement approximatif - avant l’installation de l’appareil Avant d’encadrer votre appareil, déterminez les exigences d’évent avant de décider de l’emplacement final de l’appareil. Après un cadre rugueux, placez l’appareil dans sa position finale. Consultez également le manuel de l’appareil pour l’installation du pare-brise, l’installation des onglets de clous, l’installation électrique, l’installation de gaz, etc.
  • Page 43 All manuals and user guides at all-guides.com 8.0 encadrement fini - après l’installation de l’appareil dégagements minimaux de l’enceinte note: Les appareils équipés d’un contrôle dynamique de la chaleur peuvent être construits avec un encadrement et une finition combustibles, sauf indication contraire. Il existe différents types d’options d’ouverture de ventilation.
  • Page 44 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte Un côté encastré AVERTISSEMENT • Les composants ombragés (cadrage de finition) doivent être des matériaux incombustibles. Plafond note: Le cadrage de finition doit être construit une fois que l’appareil a été...
  • Page 45 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte voir à travers flush Plafond note: Le cadrage de finition doit être construit une fois que l’appareil a été placé dans sa position finale et Ventilation branché. Bien que la hauteur minimale de l’enceinte pour la série LV soit de Cloison 73 po, certaines configurations...
  • Page 46 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte Voir-construit Plafond Cloison sèche Isolation note: Le cadrage de finition doit être construit une fois que l’appareil a été placé dans sa position finale et ventilation branché. Option 2 illustrée (appareil non représenté) minimum framing LV38-1 LV50-2...
  • Page 47 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 9.0 restriction de placement des attaches 2” 1 1/2” 6” 8” Aucun élément de fixation n’est autorisé. Aucune attache autorisée avec une pénétration supérieure à 3/4 “dans l’appareil. Lors de la sécurisation des non combustibles, nous vous suggérons d’utiliser un adhésif de construction à haute température à...
  • Page 48 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 10.0 finitions Avec Dynamic Heat Control ™, vous pouvez termi- ner l’appareil avec des matériaux combustibles, à l’exception des appareils avec installation encastrée. L’ouverture de la sortie d’air doit être située hors de la portée de l’utilisateur.
  • Page 49 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 11.0 dégagements minimaux de la tablette combustible AVERTISSEMENT • Risque d’incendie. Maintenir tous les espaces spécifiés pour les espaces combustibles. Le non-respect de ces instructions peut provoquer un incendie ou provoquer une surchauffe de l’appareil. Assurez-vous que tous les dégagements (c’est-à-dire le dos, le côté, le haut, l’évent, le manteau, l’avant, etc.) sont clairement maintenus.
  • Page 50 All manuals and user guides at all-guides.com 12.0 protrusion maximale dégagements minimaux de l’enceinte AVERTISSEMENT • Le matériau de finition incombustible serré sur le châssis autour du cadre de la barrière de sécurité (PSB) ne doit pas dépasser plus de 4“ (10cm) de la face de la barrière de sécurité (au-dessus de la porte et des côtés seulement).
  • Page 51 All manuals and user guides at all-guides.com dégagements minimaux de l’enceinte 13.0 liste complète de vérification de l’installation DHC™ SEUL CÔTÉ AVERTISSEMENT • Assurez-vous que les plaques knock-out du côté fixe ne sont pas enlevées ou endommagées (uniquement sur un seul côté). Cadre avant installé...
  • Page 52 NAPOLÉON CÉLÈBRE PLUS DE 40 ANS D’EXISTENCE CONSACRÉS À LA CONCEPTION DE PRODUITS DE CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686...