7
Transport
Transport in the original packaging or in optionally available
transport box.
8
Storage
Storing the whole system:
– Remove respiratory filter and rechargeable battery.
– Dry the components in a container or cabinet. Store them
dry and clean and protect them from direct sunlight and
thermal radiation.
Storing rechargeable batteries:
– Deeply discharged batteries may get damaged after
prolonged storage. Charge the rechargeable batteries to
50 to 70 % prior to storage.
– If storage lasts for over 6 months, charge the
rechargeable batteries intermittently.
– Do not store rechargeable batteries for prolonged periods
outside the recommended temperature range. This might
reduce the remaining capacity and number of potential
charge cycles.
9
Disposal
Dispose of the product according to local waste disposal
regulations.
10
Technical data
10.1 Overall system
Flow of respiratory protective
device/helmet/visor:
Flow of full facepiece:
Rated period of service:
1) 2)
Operating temperature
Working and storage humidi-
1)
ty
1)
Storage temperature
Noise:
International Protection Code IP 65
1) Battery charger and rechargeable batteries, see separate information
in this chapter. Other components, see corresponding instructions for
use.
2) For X-plore 8700: +14 °F to +122 °F (-10 °C to +50 °C).
Instructions for use
|
Dräger X-plore
170/190/210 L/min
115/130/145 L/min
4 hours with rechargeable
standard battery
8 hours with rechargeable
high-capacity battery
+14 °F to +140 °F (-10 °C to
+60 °C)
≤ 95 % relative humidity
-4 °F to +140 °F (-20 °C to
+60 °C )
approx. 64 dB(A)
®
8000
RFID
Technology
Frequency range
Broadcast transmission
capacity
Bluetooth
Technology
Frequency range
Broadcast transmission
capacity
10.2 Rechargeable batteries
1)
Operating temperature
Operating/storage area
humidity:
Storage temperature
Charging temperature:
1) For rechargeable batteries for X-plore 8700 in explosion-hazard
areas:
+14 °F to +122 °F (-10 °C to +50 °C)
Rechargeable standard battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow and the employed respiratory fil-
ter and facepiece type
Rechargeable high-capacity battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow and the employed respiratory fil-
ter and facepiece type
|
Transport
Induction transfer
13553 to 13567kHz
-2.30 dBµA/m (10 m)
FHSS 2.4 GHz (BT 2.1 +
EDR)
2402,0 to 2483,5 MHz
0.97 mW / -0.14 dBm EIRP
+14 °F to +131 °F (-10 °C to
+60 °C)
≤ 95 % relative humidity
-4 °F to +122 °F (-20 °C to
+50 °C)
+32 °F to +122 °F (0 °C to
+50 °C)
< 4 hours
1)
approx. 4 hours
10.8 V
3.35 Ah
36 Wh
< 4 hours
1)
approx. 8 hours
10.8 V
6.70 Ah
72 Wh