Tableau 50. Exemple de configuration fonctionnelle pour les commutateurs 1 et les commutateurs 2 ToR
Commutateur 1
!
class-map type application class-iscsi
!
policy-map type application policy-iscsi
!
interface vlan1
description Cluster_Network
no shutdown
!
interface vlan200
description iSCSI_Network
no shutdown
!
interface vlan300
description NVMe_Network
no shutdown
!
interface vlan400
description RepBlockImport_Network
no shutdown
!
interface vlan500
description NAS_Network
no shutdown
!
interface port-channel10
description NodeA_NAS_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 500
mtu 9216
spanning-tree port type edge
vlt-port-channel 10
!
interface port-channel20
description NodeB_NAS_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 500
mtu 9216
spanning-tree port type edge
vlt-port-channel 20
!
interface port-channel30
description NodeA_Cluster_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
mtu 9216
spanning-tree port type edge
vlt-port-channel 30
!
interface port-channel40
description NodeB_Cluster_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
mtu 9216
spanning-tree port type edge
vlt-port-channel 40
!
interface port-channel50
description Uplink
no shutdown
switchport mode trunk
switchport access vlan 1
Commutateur 2
!
class-map type application class-iscsi
!
policy-map type application policy-iscsi
!
interface vlan1
description Cluster_Network
no shutdown
!
interface vlan200
description iSCSI_Network
no shutdown
!
interface vlan300
description NVMe_Network
no shutdown
!
interface vlan400
description RepBlockImport_Network
no shutdown
!
interface vlan500
description NAS_Network
no shutdown
!
interface port-channel10
description NodeA_NAS_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 500
mtu 9216
spanning-tree port type edge
vlt-port-channel 10
!
interface port-channel20
description NodeB_NAS_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 500
mtu 9216
spanning-tree port type edge
vlt-port-channel 20
!
interface port-channel30
description NodeA_Cluster_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
mtu 9216
spanning-tree port type edge
vlt-port-channel 30
!
interface port-channel40
description NodeB_Cluster_LACP_port_channel
no shutdown
switchport mode trunk
switchport access vlan 1
mtu 9216
spanning-tree port type edge
vlt-port-channel 40
!
interface port-channel50
description Uplink
no shutdown
switchport mode trunk
switchport access vlan 1
Autres opérations de configuration de Dell EMC PowerSwitch Series