TECHNICAL DATA

Production code....................................................................................
..........................................................................................................
Rated input ...........................................................................................
Output ...................................................................................................
No-load speed ......................................................................................
Speed under load .................................................................................
Rate of percussion under load..............................................................
Impact energy per stroke according to EPTA-Procedure 05/2009 ............
Impact energy per stroke (pre 2009) ....................................................
Drilling capacity in concrete ..................................................................
Tunnel bit in concrete, bricks and limestone ........................................
Core cutter in concrete, bricks and limestone ......................................
Weight according EPTA-Procedure 01/2003 ........................................
Noise Information PN 11 E
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) ....................................................
Sound power level (K = 3 dB(A)) ........................................................
Wear ear protectors!
Noise Information PM 10 E
Typically the A-weighted sound pressure level of the
tool is ....................................................................................................
Measured values determined according to 2005/88/EG at the user's ear.
2005/88/EC: Conformity assessment procedure according to Annex
VI. Notified Body:
VDE Testing and Certification Institute, Merianstr. 28,
63069 Offenbach, Germany
Measured sound power level ............................................................
Guaranteed sound power level .........................................................
Wear ear protectors!
Vibration Information
Total vibration values (vector sum in the three axes) determined
according to EN 60745.
Vibration emission value a
:
h
Hammer-drilling in concrete..................................................................
Uncertainty K = ....................................................................................
Chiselling ..............................................................................................
Uncertainty K = ....................................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745 and
may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications, with
different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but
not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep the
hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing loss.
Use auxiliary handles supplied with the tool. Loss of control can
cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord. Cutting accessory
contacting a „live" wire may make exposed metal parts of the power
tool „live" and could give the operator an electric shock.
Appliances used at many different locations including open air
should be connected via a residual current device of 30 mA or less.
Always wear goggles when using the machine. It is recommended
to wear gloves, sturdy non slipping shoes and apron.
Sawdust and splinters must not be removed while the machine is
running.
Always disconnect the plug from the socket before carrying out any
work on the machine.
Only plug-in when machine is switched off.
20
ENGLISH
PN 11 E
PM 10 E
......................... 4422 44 01... .................. 4320 66 01...
......................... 4171 75 01... .................. 4171 80 01...
...000001-999999
...000001-999999
........................... 1700 W .............................. 1600 W
............................. 850 W ................................ 800 W
......................125-250 min
.................................-
-1
......................125-250 min
.................................-
-1
....................975-1950 min
...................975-1950 min
-1
-1
............................... 20 J ................................... 20 J
............................... 27 J ................................... 27 J
..........................28-50 mm ..................................-
..........................50-80 mm ..................................-
........................45-150 mm ..................................-
............................ 11,8 kg .............................. 11,0 kg
............................. 100 dB (A)
..............................111 dB (A)
................................... ..................................... 91 dB (A)
................................... ................................... 102 dB (A)
................................... ................................... 105 dB (A)
............................ 12,5 m/s
2
................................. 2 m/s
2
............................... 11 m/s
.............................. 11 m/s
2
2
................................. 2 m/s
2
................................ 2 m/s
2
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
When working in walls ceiling, or floor, take care to avoid electric
cables and gas or waterpipes.
Under the effect of extreme electromagnetic interferences from the
outside, tempo-rary variations in the speed of rotation could arise in
particular cases.
The dust that arises when working with this tool can be detrimental
to health and therefore not reach the body. Wear a suitable dust
protection mask.
SPECIFIED CONDITIONS OF USE
PN 11 E: The pneumatic hammer can be universally used for
hammer drilling and chiselling in stone and concrete.
PM 10 E:
The hammer can be used for chiselling and demolition.
Do not use this product in any other way as stated for normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfills all the relevant regulations and the
directives 2011/65/EU (RoHs), 2006/42/EC, 2004/108/EC, 2005/88/
EC (PM10E) and the following harmonized standards have been
used:
EN 60745-1:2009 + A11:2010
EN 60745-2-6:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Winnenden, 2012-12-13
Alexander Krug
Managing Director
Authorized to compile the technical file.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the system
voltage indicated on the rating plate. It is also possible to connect to
sockets without an earthing contact as the design conforms to safety
class II.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
Important note! If the carbon brushes are worn, in addition to
exchanging the brushes the tool should be sent to after-sales
service. This will ensure long service life and top performance.
Use only AEG accessories and spare parts. Should components
need to be exchanged which have not been described, please
contact one of our AEG service agents (see our list of guarantee/
service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the machine type printed as well as the six-digit No. on the label and
order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before starting
the machine.
Always disconnect the plug from the socket before
carrying out any work on the machine.
Accessory - Not included in standard equipment,
available as an accessory.
Do not dispose of electric tools together with
household waste material! In observance of European
Directive 2002/96/EC on waste electrical and
electronic equipment and its implementation in
accordance with national law, electric tools that have
reached the end of their life must be collected
separately and returned to an environmentally
compatible recycling facility.
Class II construction, tool in which protection against
electric shock does not rely on basic insulation only,
but in which additional safety precautions, such as
double insulation or reinforced insulation, are
provided.