en - Technical details

Electrical version and electrical data

Connection voltage
Frequency
Total amps.
Max. fuse (time delay fuse)
Mimimum circuit ampacity

Water connection

Cold water connection

Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied

Hot water connection

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Hot water connection (for variants without heating or with reduced heater rating)

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Hard water connection (optional)

Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Drainage

Maximum drain water temperature
Waste water connection (on machine)
Drain (on site)
Maximum drainage rate

Connection for equipotential bonding

Male thread
Toothed washers
20
208/240 V   3 Ph
3 X 49.2 A
3 X 49.2 A
1.45-145 psi (100-1000 kPa/1-10 bar)
31.5 l/min
3 x 61" (1.55 m)
158 °F (70 °C)
1.45-145 psi (100-1000 kPa/1-10 bar)
61" (1.55 m)
194 °F (90 °C)
1.45-145 psi (100-1000 kPa/1-10 bar)
61" (1.55 m)
1.45-145 psi (100-1000 kPa/1-10 bar)
2 x 61" (1.55 m)
203°F (95°C)
Plastic pipe HT DN 70
Connection DN 70
200 l/min
60 Hz
3 X 50 A
3 x 3/4"
16 l/min
1 x 3/4"
16 l/min
1 x 1"
32 l/min
2 x 3/4"
M10
M10