9. Loosen rear air shutter screw and rotate handle to the
right until full open is achieved and tighten down screw.
See Figure 7.
10. Repeat with front.
REAR AIR
FRONT AIR
SHUTTER
SHUTTER
SCREW
SCREW
OPEN
CLOSED
11. Using a 7/16 inch open wrench, loosen pilot body by
slightly turning counter-clockwise. Slide orifice bracket
to other side and tighten pilot body clockwise. See
Figure 8.
"LP" MARKING
(HOLE, RED PAINT)
12. Replace items removed in steps 2-5 in reverse order.
13. Gas conversion completed.
41339-2-0220
REAR
FRONT
Figure 7
Figure 8
Empire Comfort Systems Inc. • Belleville, IL
Check the main burner flame and pilot burner flame for
proper flame characteristics, as outlined in the Installation
Instructions and Owner's Manual.
VERIFY INPUT RATE OF CONVERTED FIREPLACE
Check the input of the fireplace.
1. Turn off all other gas appliances. Clock the gas meter
and determine the number of seconds required to
consume one cubic foot of gas.
2. 3600 ÷ time (in seconds) = cu. Ft. per hour.
3. Then cu. Ft. per hour x heating value of gas = input
rate (Btuh). On installation without gas meters, check
manifold for proper pressure.
If fireplace is not installed or product registration card has
not been returned to Empire Comfort Systems, check
off type of gas converted to on the card. Also indicate
conversion by adding "Conv." behind type of gas.