Problem
The appliance is not
charging.
The mini Turbo brush does
not function properly.
When I use my vacuum
cleaner I sometimes feel
static electricity shocks.
Using the water tank
Problem
The water flow from the
water tank is reduced.
Possible cause
The magnetic connector is not
connected properly to the
charging disk or the adapter is
not inserted into the wall
socket properly.
You have not connected the
adapter supplied.
The Vacuum & Wipe nozzle is
attached while charging the
appliance on the wall-
mounted charging station.
The roller brush is blocked.
The roller brush is blocked by
fabric or surfaces during
cleaning.
The roller brush is not properly
inserted into the mini Turbo
brush.
Your vacuum cleaner builds up
static electricity. The lower the
air humidity, the more static
electricity the appliance builds
up.
You vacuumed up dust and
dirt. This also causes static
electricity.
Possible cause
The wetting strip is blocked by
dirt.
The microfiber mopping pad is
not placed correctly and blocks
the wetting strip as a result.
This prevents water from
flowing out of the wetting
strip.
Solution
Make sure that the magnetic connector is
connected properly to the charging disk
and that the adapter is inserted into the
wall socket properly.
Make sure that you use the adapter
supplied.
Make sure that you attach the 360° suction
nozzle when you charge the appliance on
the charging station.
If you have checked the above and the
appliance still does not charge, take it to a
Philips service center or contact the
Consumer Care Center.
Remove hairs from the brush with a pair of
scissors (see user manual).
Keep the mini Turbo brush aligned with
the surface and do not push the Turbo
brush into soft surfaces.
Make sure that roller brush and the mini
Turbo brush are properly connected and
that there is no gap between the parts (see
user manual).
Discharge the appliance by frequently
holding the tube against other metal
objects in the room (for example the legs
of a table or chair, etc.). You can also raise
the air humidity level in the room.
Empty the dust container and clean the
filter (Fig. 8) according to the instructions
in the user manual.
Solution
Remove the wetting strip and clean it.
Make sure that you place the mopping pad
correctly. Check the user manual for
proper placement.