Specifications

Installation Requirements

Follow all minimum clearances to combustible surfaces
shown in the illustration on page 6.

Electrical Requirements

Installation must comply with all applicable electrical
codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on page 6.
A separate circuit servicing only this appliance is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors. A 4-conductor cord
is required for installations where grounding through the
neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
RATING PLATE
Rating plate location
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
wolfappliance.com | 5