Maintenance; Cleaning The Air Filters - Toshiba RAV-HM301MUT-E Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
7

Maintenance

WARNING
Cleaning the air filter and other parts of the air filter involves dangerous work in high places, so be sure
to have a qualified installer or qualified service person to do it.
Do not attempt it by yourself.
CAUTION
CAUTION
Do not push buttons with wet hands.
Doing so may result in electric shock.

Cleaning the air filters

• When the filter indicator is displayed on the remote controller, clean the air filters.
(Only for RBC-AMTU*** and RBC-AMSU*** remote controllers.)
• Clogged filters may lower the cooling and heating performance.
When the unit will not be used for a long time
1. Perform the fan operation for a couple of hours to dry inside.
2. Stop the air conditioner with the remote controller and turn off the circuit breaker.
3. Clean the air filters and reinstall them.
Before the cooling season
Clean the drain pan
• Contact the dealer where you purchased the product.
(Drain does not work if the drain pan or vent is clogged. In some cases the drain may overflow and wet the wall or floor. Be
sure to clean the drain pan before the cooling season.)
101-EN
– 51 –
Check periodically
• If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water
depending on the heat, humidity, or dust.
• In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where
you purchased it.
NOTE
For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in
use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended.
Furthermore, regularly check the outdoor unit for rust and scratches, and remove them or apply rustproof treatment, if
necessary.
As a general rule, when an indoor unit is operated for 8 hours or more daily, clean the indoor unit and outdoor unit at
least once every 3 months. Ask a professional for this cleaning / maintenance work.
Such maintenance can extend the life of the product though it involves the owner's expense.
Failure to clean the indoor and outdoor units regularly will result in poor performance, freezing, water leakage, and even
compressor failure.
Maintenance List
Part
Unit
Heat exchanger
Indoor / outdoor
Fan motor
Indoor / outdoor
Indoor
Filter
Indoor
Fan
Air intake / discharge
Indoor / outdoor
grilles
Drain pan
Indoor
Ceiling panel,
Indoor
louvers
Exterior
Outdoor
Check (visual / auditory)
Maintenance
Dust / dirt clogging, scratches
Wash the heat exchanger when it is clogged.
Take appropriate measures when abnormal sound
Sound
is generated.
• Wash the filter with water when it is contaminated.
Dust / dirt, breakage
• Replace it when it is damaged.
• Vibration, balance
• Replace the fan when vibration or balance is
terrible.
• Dust / dirt, appearance
• Brush or wash the fan when it is contaminated.
Fix or replace them when they are deformed or
Dust / dirt, scratches
damaged.
Dust / dirt clogging, drain
Clean the drain pan and check the downward slope
contamination
for smooth drainage.
Wash them when they are contaminated or apply
Dust / dirt, scratches
repair coating.
• Rust, peeling of insulator
Apply repair coating.
• Peeling / lift of coat
102-EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rav-hm401mut-eRav-hm561mut-e

Table des Matières