babymoov Babyphone Slim Notice D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
When EL is set, the distance check alarm symbol
screen and the receiver will set off an alarm whenever the receiver is more than
25 m away from the baby.
N.B. When setting the transmitter for the distance check, the receiver must be close
to the transmitter, i.e. less than 5 m away. The receiver will confirm the EL setting
on the transmitter by showing a letter
Alarm out-of-range setting
On - Out-of-range alarm function active
oFF - Out-of-range alarm function deactivated
N.B. When EL is selected, the out-of-range alarm function on the transmitter is always on On and cannot
be set for oFF. At the same time, the receiver will automatically go into range check mode (as indicated by
the letter
on the screen) whether the out-of-range setting is on On or oFF.
Different setting combinations are possible:
Alarm out-of-range setting
on the transmitter
On
On
oFF
oFF
EL
Temperature indication
The normal operating range for the sensor is -8 °C to + 49 °C. The sensor may take a few seconds before
displaying the temperature in the room.
N.B. If the transmitter is in "cradle song" mode for more than 10 minutes, the temperature generated
inside the unit will prevent the temperature detection from operating correctly. It may indicate 2 or 3
degrees above the actual temperature of the room.
A / Transmitter
1. Place the transmitter about 1 m from the cradle, directing the microphone (7) towards the baby.
2. Press and hold the microphone button (4) (the loudspeaker symbol will disappear from the screen). At
the same time use the selection button (2) to adjust the microphone sensitivity (volume indicator = bar
chart on the screen). The more bars you show, the more sensitive the microphone is to sounds.
3. As soon as the transmitter detects a sound, the screen lights up and the transmission symbol
4. By pressing briefly on the transmitter mode button (3), the various settings will be displayed according
to a cycle:
The out-of-range alarm
function is active
in the right part of the screen.
Alarm out-of-range setting
on the receiver
On
oFF
On
oFF
On or oFF
OPERATION
BABYPHONE SLIM • Instruction manual
will be displayed on the
Alarm function normal condition
No alarm set off when out-of-range situation
detected
Continuous alarm set off whether out-of-
range situation detected or not
No alarm set off when out-of-range situation
detected
Alarm set off when the distance exceeds
25 m (provided that
receiver screen)
The current temperature in
baby's room is 23 °C
Channel 2 and digital code 8
are selected
High power
is selected
Remarks
is shown on the
is displayed.
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

A014000

Table des Matières