Festool OF 1010 Q Notice D'utilisation D'origine page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Router
Technical data
Power
Speed (no load)
Quick height adjustment
Fine height adjustment
Drive shaft connection of the spindle M16x1.5
Router diameter
Weight (excluding cable)
Degree of protection
The specifi ed illustrations can be found at the beginning of the operating instructions.
Symbols
Warning of general danger
Wear ear protection!
Wear protective goggles!
Read the Operating Instructions/Notes!
1
Intended use
The routers are designed for routing wood, plas-
tics and similar materials.
Aluminium and plasterboard can also be proc-
essed with corresponding cutters such as are
listed in the Festool catalogues.
The user is liable for damage and injury
resulting from incorrect usage!
2
Safety instructions
2.1
Rules
WARNING! Read all safety warnings and
all instructions. Failure to follow the warn-
ings and instructions may result in electric shock,
fi re and/or serious injury.
Save all warnings and instructions for future
reference.
The term „power tool" in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
2.2
Tool-specifi c safety rules
- Do not exceed the maximum speed specifi ed on
the tool and/or keep to the speed range.
- The clamping collet should only be used to
clamp tools with a shank diameter appropriate
for the collet.
OF 1010 EBQ
1010 W
10000 - 24000 rpm
55 mm
8 mm
max. 35 mm
2.7 kg
/ II
- Check that the cutter is fi rmly fi tted and runs
freely.
- The clamping collet and union nut must show
no signs of damage.
- Cracked or distorted cutters must not be
used.
- Festool electric power tools should only be in-
stalled in work benches specially designed by
Festool. The electric power tool may become
unsafe and cause serious accident if installed
in benches from other manufacturers or self-
manufactured work benches.
3
The typical values determined in accordance with
EN 60745 are:
Sound-pressure level/sound-power level
OF 1010 EBQ, OF 1010 EQ
OF 1010 Q
Measuring uncertainty allowance
Overall vibration levels (vector sum for three
directions) measured in accordance with EN
60745:
Vibration emission level
(3-axis)
Front handle
Uncertainty
The emission values specifi ed (vibration, noise)
were measured in accordance with the test con-
ditions stipulated in EN 60745 and are intended
for machine comparisons. They are also used for
12
OF 1010 EQ
1010 W
9500 - 23000 rpm
55 mm
8 mm
M16x1.5
max. 35 mm
2.7 kg
/ II
Wear suitable protection such as
ear protection, safety goggles, a
dust mask for work which gener-
ates dust, and protective gloves
when working with raw materials
and when changing tools.
Noise and vibration information
Wear ear protection!
OF 1010 Q
720 W
26500 rpm
55 mm
8 mm
M16x1.5
max. 35 mm
2.7 kg
/ II
79/90 dB(A)
87/98 dB(A)
K = 3 dB
2
a
= 5,5 m/s
h
2
a
= 8,0 m/s
h
K = 2,0 m/s²