Problem
Description
Battery
The temperature of
temperature
the EFOY GO! is too
high / too low.
12 V
The load on the 12 V
connection
connection is too high
overload /
or a short circuit has
short circuit
occurred.
230 V
The load on the 230 V
connection
connection is too high
overload /
or a short circuit has
short circuit
occurred.
Internal
An internal error has
error*
occurred.
Faults and remedies
Solution
Wait until the EFOY
GO! has cooled down
/ warmed up. Then
switch the EFOY GO!
back on.
Disconnect the load
from the 12 V
connection and
switch the EFOY GO!
back on. Please
check the current
consumption of your
load (I < 10 A).
Disconnect the load
from the 230 V
connection and
switch the EFOY GO!
back on. Please
check the power
consumption of your
load (P < 400 W).
Switch the EFOY GO!
back on. If the error
occurs again, please
contact the EFOY
Hotline. You will find
contact details in
chapter 1.2 "Service
contact" on page 23.