Set the high temperature limit
stop**
Remove the clip and stop ring from the cartridge
stem.
Turn the water on to one of the functions.
Turn the cartridge stem until the output water
is the desired high temperature, usually 110°
- 112° F**.
Replace the stop ring so that the tooth is against
the cartridge stop. Replace the clip.
It should not be possible to turn the stem further
counter-clockwise.
**Follow all applicable local plumbing codes when setting the
high temperature limit stop.