01.01 Setting up room
Separate electrical units should not be used in the same room as the steam panel.
The steam panel is designed to be mounted on the wall.
Pay attention to the ceiling height of the room when installing the steam panel.
There must be clearance of at least 50 mm above the steam panel to the ceiling.
The cabin has been designed for installation on masonry walls. Reinforce other types of walls (wood, plaster) to ensure secure
attachment.
The walls must be completely tiled over the cubicle's entire height before the fi tting.
Walls must be straight.
The fl oor at the place of installation must be completely fl at.
For the safety reasons this device should not be used by physically and mentally disabled people (and children) or by people without
relevant experience or knowledge, unless they use it, under supervision of relevant persons or get the instruction how to use it.
Children should use this product only under adult's supervision.
Attention: due to high temperature within the working area of steam jet and at steam outlet, direct skin contact should
be avoided.
- warning! Hot surface!
Silicone must be provided by building constructor. Please keep in mind that maintenance joints may require
cleaning.
02

Equipment

GB
Column made of aluminium.
Integrated control panel.
Steam generator 3,3 kW (bis 3m³) / 4,0 kW (bis 3,5m³), with semi-automatic cleaning nominal voltage 230 V, 50/60 Hz.
Steam nozzle.
Fittings (chrome-plated) consisting of:
hand shower, rain shower, thermostat ½", 1 closing valve.
Rain shower electronically operated
Sound Module: Bluetooth, Radio, 2 speakers
2 LED spot lights with automatic colour changer.

02.01 Fittings technical data

Recommended fl ow pressure:
Hot water temperature:
Recommended hot water temperature:
Temperature range:
Safety cut-off :

02.02 Steam generator technical data

Steam generator
Voltage
Fuse protection
Line cross section
Water connection (Cold Water + Hot Water)
Steam output
12
200-500 kPa
max. 90°C
60-70°C
20-60°C
38°C
3,3 kW
16 A
4,2 kg/h
4 kW*
1N~230 V, 50/60 Hz
20 A
3 x 2,5 mm²
R½"
6,5 kg/h