a) Current measuring „a"
proceed as follows to measure „aC" (a~) currents:
- Turn the meter on at the
rotary switch and select one
of the two measuring ranges
in „A~" (40 or 400).
- Open the clamp meter sensor
with the lever (3) and
encirle the cable which is to
be measured and reclose the
clamp meter sensor. The
measured value is indicated
on the display
- After measuring, remove the measuring leads from the measured object and turn
the meter off. Turn the rotary switch to „OFF".
proceed as follows to measure direct currents DC (a
- Turn the meter on at the rotary switch and select one of the two measuring ranges
in „A
" (40 or 400).
- Open the clamp meter sensor with the lever (3) and encirle the cable which is to
be measured and reclose the clamp meter sensor. The measured value is indicated
on the display
Only ever clamp one cable. If you clamp several cables, the cur-
rents will cancel one another out and you will not get a measure-
ment. The permanent magnetism of the current sensor may lead
to a small current being shown in the display even when no cable
is clamped. To set the display to „0", press the REL button before
measuring (8).
) (11 1412 only):