6 STANDARD PROGRAMMING

1 Power Supply
Give power supply, the display shows the following symbols "
*
If the control panel has already been programmed and the power fails or is switched off - once power is returned and a START command
is given, the position reset procedure is performed (see "rESP" in the table "WORKING STATUS MESSAGES" on page 26.
2 Visualisation of inputs and operations-counter status
1. Press the
key for 15 seconds;
2. The display will show respectively:
Inputs status (check it's correct);
Total operations counter (* see P064):
i.g.:
= 3x1000* = 3000 operations performed
Maintenance operations-counter (* see P065):
i.g.:
= 5*x500 = 2500 operations remaining be-
fore the maintenance intervention request (
noeuvres-counter disabled)
3. Hold down the
key to display a cyclic 3 options, or rele-
ase the
button to exit the parameter.
3 Selection type of operators
1. Scroll down the parameters with
lise P028;
2. Access the parameter by pressing the
3. Verify that the value corresponds to d000 (GEKO), otherwise, you
must select it by pressing
4. Confirm your choice by pressing the
to P028).
4 Selection operating with or without encoder
Warning: Remember to correctly set the jumpers J5 and J9.
1. Scroll down the parameters with
lise P029;
2. Access the parameter by pressing the
3. Acting on
and
keys, set:
- d000=for operators with encoder;
- d001=for operators without encoder;
4. Confirm your choice by pressing the
to P029).
= ma-

! IMPORTANT !

and
keys until you visua-
key;
and
keys;
key (display returns again
and
keys until you visua-
key;
key (display returns again
", "
", "
" and then "- - - -".