If the variation is done on both sides, the references are summed together (e.g. 2" + 1"=3" increase), starting
from a 20" base, we can reach a maximum of 24".
13.1 ADDITIONAL ADJUSTMENTS OF THE TURNTABLE LOCKING MEASUREMENTS
The values changed previously can be increased further still by moving the position of the 4 jaws as shown in
the following figures.
The increase in the locking diameter varies + 0" up to a maximum of + 2" to sum to the increase obtained with
the changes seen in the previous paragraph.
To change the position:
Undo the screw (1) with an Allen wrench
Remove the locking jaw (2) and the sliding element (3)
Position the hole of the sliding element by the guide hole (4) based on the locking dimensions wanted. Refer to
the measurements given below.
Reposition the jaw and lock with the screw (1) ensuring that the tightening torque is 72 Nm.
ATTENTION: it is important that the above steps are performed identically on all 4 tightening jaws to pre-
vent any unbalance when locking.
2
4
1
3
+ 0"
+ 1"
+ 2"
fig. 17