WARNING DEA System reminds all users that the selection, positioning and installation of all ma-
terials and devices which make up the complete automation system, must comply with the European
Directives 98/37/CE (Machinery Directive), 89/336/CE and subsequent amendments (electromagnetic
compatibility), 2006/95/CE and subsequent amendments (low voltage electrical equipment). In order
to ensure a suitable level of safety, besides complying with local regulations, it is advisable to comply
also with the above mentioned Directives in all extra European countries.

5 TECHNICAL DATA

Power supply ....................................................230 V a.c. +/- 10% 50Hz
Flashing light output .........................................230 V a.c. 50Hz max 40W
Auxiliary power supply output (+24VAUX) ..........24 V a.c. max 200mA
Safety devices power supply output (+24VSIC) ...24 V a.c. max 200mA
Electric lock output ............................................12 V a.c. max 15 VA
LC/SCA contact capacity ...................................max 5A
Max motor capacity ..........................................2 X 500Wmax
Protection level .................................................IP55
Fuse F1 ............................................................T5A
Fuse F2 ............................................................T160mA
Radio receiver frequency ...................................433,92 MHz rolling code / dipswitch coding
Max. number of transmitter controlled................100

6 OPERATING CONDITIONS

202RR control board is designed for the automation of swing gates operated by 230 V a.c. motors.
This control board has been designed and tested for operation under "normal" conditions for both
residential and industrial use. The level of protection against dust and water and other data are illustrated
in "5 Technical Data".
WARNING Using the product under unusual conditions not foreseen by the manufacturer may
cause dangerous situations; this is the reason why all the conditions prescribed in these instructions
must be followed.
WARNING Under no circumstance must the product be used in an explosive environment or sur-
roundings that may prove corrosive and damage parts of the product.

7 ASSEMBLY AND WIRING INSTRUCTIONS

WARNING To ensure an appropriate level of electrical safety always keep very low tension cables (controls,
electric lock, aerial and auxiliary circuits power supply) separate from (min 4 mm if not insulated, 1 mm through
insulation) 230V power supply cables. To keep them apart put cables inside a tubing tray and fasten them with
clamps near the terminal board. Make sure cables are not damaged or worn off during installation.
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
WARNING Install the control board according to the instructions given in "F3 Installation". Drill
only the holes foreseen by the manufacturer to allow for wires passage, and use the specified clamps.
Failure to comply with these instructions may jeopardise the level of electrical safety.
Connect to the power supply 230 V a.c. ± 10% 50 Hz through a multi pole switch or a different device
that can ensure multi pole disconnection from the power supply, with a contact opening of 3,5 mm. Use
a cable with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
Make all connections to the terminal board and remember to short-circuit, whenever necessary, all
unused inputs. (See table 1 terminal board connection and Fig. 1 basic and complete wiring diagram)
Operating instructions and warnings
250V (retarded)
250V (retarded)
A1
A2
A3
17
2 0 2 R R
R

Publicité