Honeywell Home HE120 Instructions D'installation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HE120 BY-PASS DRUM HUMIDIFIER
Fig. 24. Correct Float Valve position.
FLOAT VALVE
WASHER
(RECESSED SIDE)
Fig. 25. Re-installing Float Valve.
7. Insert the Valve Hole Plug in the "D" hole on the
opposite side of the Float Valve. See Fig. 26.
Fig. 26. Installing Valve Hole Plug.
8. Insert the Drain Fitting into the bottom of the Humidi-
fier on the same side as the Bypass Duct. See Fig. 27.
69-1860EF—02
MOTOR
FLOAT VALVE
M13626
HUMIDIFIER
HOUSING WALL
FLOAT VALVE
RETAINING NUT
FLOAT VALVE STEM
M13616
VALVE HOLE PLUG
M13627
DRAIN
FITTING
Fig. 27. Installing Drain Fitting.
9. Place the Water Pan in the Humidifier Housing so
Overflow Tube is above previously installed Drain
Fitting. See Fig. 28.
OVERFLOW
TUBE
Fig. 28. Installing Water Pan.
10. Install Humidifier Drum by inserting motor coupling
end first, then snapping it into the bearing. See Fig.
29.
Fig. 29. Installing Humidifier Drum.
11. Snap Humidifier Cover into place.
12
FLOAT
M13628
DRAIN FITTING
(UNDERNEATH HUMIDIFIER HOUSING)
MOTOR
M13630
M13629