Safety Information (continued)
□ The LP-gas supply cylinder must be disconnected when this fire table is not in use.
□ Only cylinders marked "propane" shall be used.
□ Be sure to use only one 20 lb (9.1 kg) LP gas cylinder with a Type 1 valve with this fire table as required by the American National
Standards Institute (ANSI) and the Canadian Standards Steering Committee.
□ The LP gas cylinder must contain a shut-off valve as specified in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet
Connection, ANSI/CGA-V-1-1977, CSA B96.
□ Never attempt to attach this fire table to the self-contained LP gas system of a camper trailer, motor home or house. Hand turn the
manual gas control valve. Never use tools. If the valve will not turn by hand, do not try to repair it. Call a Certified Gas Technician. The
use of force or any self attempted repair may result in a fire or explosion.
□ Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner's
information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency
or the gas supplier.
□ This fire table comes equipped with a standard LP gas hose and regulator including the fire table side connection for a CGA No 791
Cylinder Connection Device. The LP gas hose and regulator supplied with this fire table must be used. Only a hose and regulator
specified by manufacturer can be used for replacement.
□ The CGA No 791 connection incorporates an excess flow limiting device that acts to limit the flow of gas if a leak is detected between
the regulator and the burner valve.
□ If the burner valve is open prior to the LP gas cylinder service valve being opened, the connection will interpret this free flow of gas to
be a leak.
□ The connection safety feature will reduce gas flow from the regulator to the fire table to a minimal level.
□ Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to ensure that the connection flow
limiting device is not triggered mistakenly.
□ If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service valve and the burner valve, wait 10
seconds to allow the device to reset, open the cylinder service valve, then open the burner valve and light the fire table as per lighting
instructions.
□ Be sure to protect the hose from any hot surfaces.
□ Serious danger may result if the hose contacts any hot surface. Regular maintenance of the hose and regulator: Inspect the hose
before each use of the fire table. If the hose shows signs of cracks, abrasions, cuts or damage of any kind, do not operate the fire table.
Fix or replace the hose as required before using the fire table. For assistance with repair or replacement of the hose, call the Customer
Service Team at 1-855-HD-HAMPTON. Use only replacement parts from the manufacturer. Inspect the seal inside the CGA No 791
service valve on the LP gas cylinder when replacing the cylinder or at least once per year. If there is any indication of damage, have the
seal replaced by a certified gas dealer before operating the fire table.
□ Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve. Hand tighten only.
□ Be careful to not cross the threads on the connection when tightening the CGA No 791 connection on to the LP gas cylinder service
valve.
□ A leak test should always be performed after attaching the connection to the LP gas cylinder service valve. (See step 2 in the Operation
section of this manual).
□ LAVA ROCK USE: Do not light or use the gas unit if lava rocks are wet. Ensure lava rocks are completely dry before lighting as
intense heat could cause the lava rocks to crack. Lava rocks could hit a person in the face or eyes during the initial start of this
unit, so please keep away from the fire table for the first 20 minutes.
□ Maximum gas supply pressure is 250 psi.