Kohler K-77685 Guide D'installation Et D'entretien page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting (cont.)
Symptoms
Probable Causes
2.
Water leaks at
A. Tubing is not cut
a tubing
connection.
3.
Water leaks at
A. The connection is
a threaded
connection.
Kohler Co.
Recommended Action
A. Turn off the water
square, or is
supply, and relieve
damaged or
water pressure. Press
crimped.
in the collar around
the fitting at the leak,
and pull the tubing
to remove. Use a
sharp utility knife to
cut 1/2" (13 mm) off
the end of the
tubing. Reinsert the
tubing into the
fitting. Turn on the
water supply and
check for leakage.
A. Turn off the water
damaged or dirty.
supply, and relieve
water pressure.
Disconnect the
fitting, and inspect
the seal for damage
or debris. Remove
any debris or replace
the damaged fitting.
Securely reconnect
the fitting, but do not
overtighten. Turn on
the water supply and
check for leakage.
9
1285422-2-A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K-77686

Table des Matières