Installation without external opening

Recycling version
Contact your supplier to obtain active carbon
filters to transform the extractor hood into a
recycling hood.
Installing the active carbon filter (cassette)
Check that the diameter of the active
carbon filter corresponds to the outlet
diameter.
If necessary, remove the pre-installed
diameter adapter.
Position the active carbon filter on the
outlet and attach it in place by turning it
anticlockwise.
Installing the active carbon filter (cut-out)
The metal filter has to be removed before
the active carbon filter is installed.
To open the metal filter, press on
the locking device and pull the filter
downwards.
Place the pre-cut filter on top of the
metal filter. Hold it in position using the
metal rods (supplied depending on the
model).
Replace the metal filter in its original
position.
PLEASE NOTE
Make sure that the filter is properly attached; otherwise,
it could become dislodged and cause a hazard.
Installing a carbon filter reduces the extraction power of
the hood.
Using the appliance