Malfunction
Hel-X biomedia are being
flushed out.
Less movement of the Hel-
X biomedia
Less movement of the new
Hel-X biomedia
8

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
► Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the
water.
► Isolate the device (disconnect from the power supply) before carrying out any work on it.
8.1

Cleaning the device

► Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or
impair the function of the unit.
► Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
► After cleaning, thoroughly rinse all parts in clean water.
8.2

Regular tasks

The filter system is self-cleaning. Carry out the following work regularly to ensure the optimum cleaning
capacity of the filter system.
Regular checks
► Check the display of the control system for any system messages. (→ System messages)
► Check the area in front of the separating plate and the inside of the filter drum for excessive soiling
(e.g. string algae). To do this, remove a screen element. (→ Removing/fitting a screen element)
Removing accumulated dirt
Dirt that cannot be collected by the filter drum, sinks to the bottom and has to be removed.
► Open the 3 in (DN 75) dirt outlet for approx. 10 seconds once per month.
► Remove accumulated dirt in front of the filter drum.
► Remove string algae from the dirt channel.
► Remove accumulated dirt from the level detection device.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Possible cause
The meshed tube has slipped.
Defective meshed tube
Aerator rod is blocked.
Aerator pump malfunction
Hel-X biomedia are not yet fully colonised.
Remedy
Correct the position of the meshed tube.
Replace the meshed tube.
Replace the aerator rod.
Check the aerator pump.
It takes several weeks for the biomedia to become
colonised by bacteria. Wait for the natural process
to take place.