XDL12TT-AM
RINS1900-1
Environmental Class (EC) IV
10.525GHz: BE, CH, CY, DK, ES, HU, IE,
9.9GHz: AT, BE, CH, CY, CZ, DK, EE, FI,
IS, IT, MT, MY, NL, NO, SE, SI, UAE, USA
FR, GR, HR, HU, IE, IS, IT, LT, MT, NL,
PL, PT, SI, TR, UAE
10.587GHz: GB, MY
EN
1. Installation
Scan the QR code for fixing instructions and adapter information. Ensure that the detector is
installed away from reflected sunlight and large objects.
2. Switches
Switch
Up (ON position)
Down
1
AC 230V, 50 Hz
AC 110V, 60 Hz
2
Anti-masking always on
Anti-masking on when disarmed
3
Blocking off
Blocking on when disarmed
4
R1 off
R1 on
5
Auto sensitivity
High sensitivity
6
Open mask & alarm relays
Open mask relay only
7
Buzzer on
Buzzer off
8
LEDs on
LEDs off
If you disable the detector's LEDs, you can remotely enable them in walk tests. Connect the
detector's LED terminal to a control panel PGM output that switches to 0V to enable the LEDs.
3. Microwave range and angle of detection
Use the highlighted dials to change the microwave range and angle of detection.
4. LEDs
Four LEDs show the status of the detector.
5. Lens inserts
Use lens inserts to control coverage.
6. Header pins
Place two-pin jumpers onto header pins to adjust resistance for alarm, masking/fault and tamper.
7. Anti-masking
Anti-masking triggers an alarm when part or all of the sensor is masked by an intruder. Use the
highlighted dial to change the masking area range. When an intruder enters the masking area,
LED2 pulses. When the intruder moves out of the masking area, if the detector does not see
activation on all 3 sensors within 1 min, the mask/fault relay opens and LED1 and LED3 turn on.
To reset, remove the obstruction and perform a walk test for 1 min.
8. Blocking
Blocking detects intruders behind objects when the panel is disarmed. To use blocking, move
switches 3 and 4 down, and connect the R1 input to a panel output that is negative when
disarmed. When blocking is active, the alarm relay opens and LED1 and LED3 turn on. To reset,
perform a walk test.
9. Connecting to CCTV and lights
To connect the detector to CCTV and lights, refer to the wiring diagram.
Specifications
Tri-detection method
Lenses
2 digital dual-element passive IR & 1 microwave
UV compensated
doppler unit
Operating voltage & current
Sensitivity
9 - 16V DC, (24mA @ 13.8V DC quiescent)
AUTO or HIGH
Relay output
Temperature compensation
3 x SELV limits, 60V DC 50mA (42.4V AC peak)
Digital
Mounting height & range
Pet immunity
1m - 1.5m = 12m range
Up to 24kg, 1m high
Tamper switches
Detection speed
12V DC 50mA both front and rear
0.25 - 2.5m/s
Temperature
Tri-masking
Storage: -40°C to 80°C
Adjustable from 0m to 1m, covers all 3
Operating: -30°C to 70°C
technologies
Dimensions & weight
Casing
188 x 77 x 84mm, 0.3kg
3mm polycarbonate, 0.4mm HDPE in Lens Area.
IP Rating: IP55
Product information
Applies to electrical products sold within the European community. At the end of the electrical product's life,
do not dispose of it with household waste. Where possible, recycle the product. Check with your Local
Authority or retailer for recycling advice in your country.
Warranty
This product is sold subject to our standard warranty conditions and is warranted again defects in
workmanship for a period of five years (excluding lens). In the interest of continuing care and design, Pyronix
Ltd reserves the right to amend specifications without giving prior notice.
 +44(0)333 444 1280 (UK)
 customer.support@pyronix.com (UK)
1
1-1.5m
4m
12m
2
1-1.5m
12m
2
ON
4
LED 1
LED 2
LED 3
LED 4
 www.pyronix.com
1-1.5m
4m
< 24kg
1m
1-1.5m
8m
12m
4m
8m
3
12m
12m
~8m
0m
5
Top PIR activated
Bottom PIR activated
Microwave activated
Alarm
Masked / blocked
Mask processing
Powering up
2
Low voltage
Top PIR failed self-test
Bottom PIR failed self-test
Microwave failed self-test
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
< 10m
1-1.5m
8m
12m
4m
8m
> 10m
1-1.5m
12m
4m
8m
2
12m
12m
1.3m
1.3m

Publicité

loading

Sommaire des Matières pour HIKVISION Pyronix XDL12TT-AM

  • Page 1 XDL12TT-AM < 10m RINS1900-1 Environmental Class (EC) IV 10.525GHz: BE, CH, CY, DK, ES, HU, IE, 9.9GHz: AT, BE, CH, CY, CZ, DK, EE, FI, IS, IT, MT, MY, NL, NO, SE, SI, UAE, USA FR, GR, HR, HU, IE, IS, IT, LT, MT, NL, PL, PT, SI, TR, UAE 10.587GHz: GB, MY 1-1.5m...
  • Page 2 3EOL DEOL +12V +12V 820R 820R 820R LED ALARM N / O LED ALARM N / O TAMPER ALARM N / C MASK / FAULT TAMPER ALARM N / C MASK / FAULT XDL12TT-AM XDL12TT-AM <1m +12V 820R LED ALARM N / O TAMPER ALARM N / C MASK / FAULT...
  • Page 3 1. Installation 1. Installation 1. Installatie 1. Installazione Scannez le code QR pour accéder aux instructions de fixation et aux informations concernant l'adaptateur. Scannen Sie den QR-Code, um Befestigungsanweisungen und Adapter-Informationen aufzurufen. Der Scan de QR-code voor installatie-instructies en adapterinformatie. Let er bij de installatie op dat de Eseguire la scansione del codice QR per le istruzioni di fissaggio e informazioni sull'adattatore.
  • Page 4 1. Instalação 1. Монтаж 1. Installation 1. Instalación Просканируйте код QR, чтобы получить инструкцию по монтажу и информацию об адаптере. Данный детектор Leia o código QR para obter instruções de montagem e informações sobre o adaptador. Certifique-se de Zeskanuj kod QR, aby uzyska instrukcj monta u i informacje o uchwycie. Czujk nale y zainstalowa z Para obtener instrucciones de fijación e información sobre el adaptador, escanee el código QR.