dixell XR06CX Mode D'emploi page 8

Masquer les pouces Voir aussi pour XR06CX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.
FRONT PANEL COMMANDS
KEYS COMBINATION
+
To lock or unlock the keyboard.
+
To enter the programming mode.
+
To return to room temperature display.
LED
HOW TO SEE THE SET POINT
1 Push and immediately release the
2 Push and immediately release the
HOW TO CHANGE THE SETPOINT
1 Push the
key for 3 seconds , the Set point is displayed and the and the "°C" or "°F" LED starts blinking;
2 To change the Set value push the
NOTE: the set value is stored even when the procedure is exited without pressing the
HOW TO START A DEFROST
Push the
key for at least 4 seconds and a manual defrost will start.
HOW TO CHANGE A PARAMETER VALUE
To change the parameter's value operate as follows:
1 Enter the Programming mode by pressing the
2 Select the required parameter through
3 Press the
key to display its value;
4 Change its value through
5 Press
again to store the new value and move to the following parameter.
To exit: Press
+
NOTE: the set value is stored even when the procedure is exited without pressing the
HIDDEN MENU
The hidden menu includes all the parameters of the instrument; how to enter the hidden menu:
1 Enter the Programming mode by pressing the
2 Released the keys, then push again the
NOW YOU ARE IN THE HIDDEN MENU.
3 Select the required parameter, browsing the displayed parameters through the
4 Press the
key to display its value;
5 Change its value through the
6 Press
to store the new value and move to the following parameter.
To exit: Press
+
NOTE: the set value is stored even when the procedure is exited by waiting the time-out to expire.
HOW TO MOVE A PARAMETER FROM L2 TO L1
Each parameter present in the second level (HIDDEN MENU) can be removed or put into "THE FIRST LEVEL" (user level) by pressing
In the HIDDEN MENU (L2) when a parameter is present in the First Level, the decimal point LED is on.
6
XR06CX
To display or change target set point,
in programming mode it selects a parameter or confirm an operation.
To start a manual defrost.
In programming mode it browses the parameter codes or increases the displayed value.
In programming mode it browses the parameter codes or decreases the displayed value.
MODE
ON
FLASHING
ON
FLASHING
ON
FLASHING
ON
FLASHING
ON
FLASHING
key, the set point is displayed;
key or wait about 5s to return to the display of the temperature.
or
arrows. Then push the
+
keys for 3s "°C" or "°F" LED start blinking;
or
keys;
or
keys;
or wait 30s without pressing a key.
+ keys for 3s. "°C" or "°F" LED start blinking;
+
keys for more than 7s. The L2 label is displayed, immediately followed by the Hy parameter.
or
keys;
or wait 30s without pressing a key.
MEANING
Compressor enabled
Anti short cycle delay enabled
Defrost in progress
Dripping in progress
Fans output enabled
Fans delay after defrost
Measurement unit
Programming mode
Measurement unit
Programming mode
again to confirm.
key.
key.
and
keys;
+
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xr70cxXw60k

Table des Matières