dixell XR06CX Mode D'emploi page 53

Masquer les pouces Voir aussi pour XR06CX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

dIXEL
Power supply: 230Vac or. 110Vac
10% or 24Vac
±
Power absorption: 10VA max.
Inputs: 4 NTC probes
Digital inputs: 1 free voltage
Relay outputs: Total current on loads MAX. 20A
compressor: relay SPST 20(8) A, 250Vac
fan: relay SPST 8(3) A, 250Vac
defrost: relay SPST 16(5) A, 250Vac
light (oA3): relay SPST 16(5) A, 250Vac
Serial output : TTL standard.
Communication protocol: Modbus - RTU
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.
Pollution grade: normal
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20
85% (no condensing)
÷
Measuring and regulation range: NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
14. CONNECTIONS
14.1 XW60K
15. Default setting values
Label Name
REGULATION
Set Set point
Differential
Hy
Minimum set point
LS
Maximum set point
US
Thermostat probe calibration
Ot
P2P Evaporator probe presence
OE Evaporator probe calibration
Third probe presence (1st cond.
P3P
1
probe)
Third probe calibration
O3
1
P4P Fourth probe presence (2nd
cond.
probe)
Fourth probe calibration
O4
OdS Outputs activation delay at start up
AC Anti-short cycle delay
Ac1 Second compressor delay
P1-P2 percentage for regulation
rtr
CCt Compressor ON time during fast
freezing
CCS Set point for continuous cycle
COn Compressor ON time with faulty probe
COF Compressor OFF time with faulty
probe
DISPLAY
Temperature measurement unit
CF
rES Resolution (integer/decimal point)
rEd Remote display
dLy Display temperature delay
P1-P2 percentage for disply
dtr
DEFROST
tdF Defrost type
dFP Probe selection for defrost termination
dtE Defrost termination temperature
IdF Interval between defrost cycles
MdF (Maximum) length for 1° defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPO First defrost after start up
dAF Defrost delay after fast freezing
FANS
FnC Fans operating mode
Fnd Fans delay after defrost
Fct Differential of temperature for forced
activation of fans
1592026020 XW60K GB R1.0 22.02.2008.doc
Installing and Operating Instructions
Range
Default Level
LS÷US
-5.0
0,1÷25,5 °C / 1÷45°F
2.0
-50,0°C÷SET / -58°F÷SET
-50.0
SET ÷ 110°C / SET ÷ 230°F
110
-12÷12°C /-120÷120°F
0.0
n=not present; Y=pres.
Y
-12÷12°C /-120÷120°F
0.0
n=not present; Y=pres.
n
-12÷12°C /-120÷120°F
0
n=not present; Y=pres.
n
-12÷12°C /-120÷120°F
0
0÷255 min.
0
0÷30 min.
1
0÷255s
5
0 ÷ 100 (100=P1 , 0=P2)
100
0 ÷ 23h 50 min.
0.0
(-55.0÷150,0°C)
-5
0÷255 min.
15
0÷255 min.
30
°C ÷ °F
°C
in ÷ de
dE
P1 ÷ 1r2
P1
0 ÷ 20.0 min (10 sec.)
0
1 ÷ 99
50
EL, in
EL
nP; P1; P2; P3; P4
P2
-50,0÷110°C / -58÷230°F
8.0
1÷120h
6
0÷255 min.
30
0÷99min
0
rt, it, SEt, dEF, dEG
it
0÷255 min.
30
0÷60 min.
0
n ÷ y
n
0 ÷ 23h 50 min.
0.0
C-n, C-y, O-n, O-y
o-n
0÷255 min.
10
0÷50°C
10
Label Name
FSt Fans stop temperature
Fon Fan on time with compressor off
FoF Fan off time with compressor off
FAP Probe selection for fan management
AUXILIARY THERMOSTAT
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Aux.output working during defrost
ALARMS
ALP Probe setting for temperature alarm
ALC Temperature alarms configuration
ALU MAXIMUM temperature alarm
ALL minimum temperature alarm
AFH Temperature alarm and fan differential
ALd Temperature alarm delay
dAO Delay of temperature alarm at start up
AP2 Probe for temperat. alarm of
condenser
AL2 Condenser for low temperat. alarm
AU2 Condenser for high temperat. alarm
Differ. for condenser temp. alar.
recovery
AH2
Ad2 Condenser temperature alarm delay
Delay of cond. temper. alarm at start
up
dA2
Compr.
off
for
temperature alarm
bLL
Compr.
off
for
temperature alarm
AC2
AUXILIARY OUTPUT
tbA Alarm relay disabling
oA3 Fourth relay configuration
AoP Alarm relay polarity (oA3=ALr)
DIGITAL INPUT
i1P Digital input polarity
i1F Digital input configuration
- - -
did Digital input alarm delay
Pr1
Nps Number of activation of pressure
Pr2
switch
Pr2
odc Compress and fan status when open
Pr1
door
Pr1
Regulation restart with door open
rrd
alarm
Pr2
HES Differential for Energy Saving
Pr2
OTHER
PbC Kind of probe
Pr2
Adr Serrial address
Pr2
onF on/off key enabling
dP1 Room probe display
Pr2
dP2 Evaporator probe display
Pr2
Pr1
dP3 Third probe display
dP4 Fourth probe display
Pr2
rSE Current set point
Pr2
rEL Software release
Pr2
Ptb Map code
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr2
Pr2
Pr1
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
dIXEL
S.p.a.
Pr2
Z.I. Via dell'Industria, 27 - 32010 Pieve d'Alpago (BL) ITALY
Pr2
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
Pr1
http://www.dixell.com
Pr1
Pr2
XW60K
Range
-50,0÷110°C / -58÷230°F
0÷15 (min.)
0÷15 (min.)
nP; P1; P2; P3; P4
CL; Ht
-50,0÷110°C / -58÷230°F
0,1÷25,5 °C / 1÷45°F
nP / P1 / P2 / P3
n, y
P1÷P4
rE÷Ab
-50,0÷110°C / -58÷230°F
-50,0÷110°C / -58÷230°F
0,1÷25,5 °C / 1÷45°F
0÷255 min.
0 ÷ 23h 50 min.
nP; P1; P2; P3; P4
(-55 ÷ 150°C) (-67÷ 302°F)
(-55 ÷ 150°C) (-67÷ 302°F)
[0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
0 ÷ 254 (min.) , 255=nU
0.0 ÷ 23h 50'
condenser
low
n(0) - Y(1)
condenser
high
n(0) - Y(1)
n=no; y=yes
ALr = alarm; dEF = do not select it;
Lig =Light; AUS =AUX; onF=always
on; Fan= do not select it; db = do
not select it; dF2 = do not select it
oP; cL
oP=opening;CL=closing
EAL, bAL, PAL, dor; dEF; Htr, AUS
0÷255min
0 ÷15
no; Fan; CPr; F_C
n – Y
-30°C÷30°C; -54°F÷54°F
Ptc; ntc
1÷247
nu, oFF; ES
--
--
--
--
-
- - -
- - -
E-mail:
dixell@dixell.com
1592026020
Default Level
2
Pr1
0
Pr2
0
Pr2
P2
Pr2
cL
Pr2
0,0
Pr2
2,0
Pr2
nP
Pr2
n
Pr2
P1
Pr2
rE
Pr2
10,0
Pr1
10,0
Pr1
2,0
Pr2
15
Pr2
1,3
Pr2
P4
Pr2
-40
Pr2
110
Pr2
5
Pr2
15
Pr2
1,3
Pr2
n
Pr2
n
Pr2
y
Pr2
Lig
Pr2
cL
Pr2
cL
Pr1
dor
Pr1
15
Pr1
15
Pr2
F-c
Pr2
y
Pr2
0
Pr2
1
Pr2
ntc
Pr1
oFF
Pr2
-
Pr1
-
Pr1
-
Pr1
-
Pr1
Pr1
1,1
Pr2
-
Pr2
51

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xr70cxXw60k

Table des Matières