4. Correct placement

Application as:
Back radiator:
Front radiator:
Ceiling radiator:
According to EN 60335-2-53, an infrared thermal cabin with a 20 cm x 20 cm
grid of averaged irradiation must not exceed 1000 W/m² on a person's chest and
back (note that this limit relates to the prevention of heat stress).
To ensure that this limit is not exceeded, only a 350 W or 500 W radiator may be
used as a back radiator. Furthermore, when positioning the back radiator, ensure
that the distance from the person's back to the radiator does not exceed 4 cm.
Only 350 W, 500 W or 750 W radiators may be used as front radiators. Ensure
that the minimum distance between the upper body and front radiator is not less
than 50 cm (in picture „x")
To ensure that the ICNIRP limit values for
the long-term limit value of 100 W/m² for
"infrared eye" are not exceeded, the radia-
tors must be moved down (in picture„Y").
Detailed information can be found in the
appraisals LE-G18/3 and LE-G31/18 con-
ducted by Seibersdorf Laboratories.
350 W, 500 W
350 W, 500 W or 750 W
750 W, 1300 W
Y
x
Front radiator
x ≥ 50 cm
p. 8/16