4. Switch off the electrical power supply and record the installation.
The power supply is not cut. Risk of electric shock !
➜ Unplug the plug or disconnect the electrical conductors and take the
steps required to avoid inadvertent operation.
5. Inspect the hydraulic parts and shredding blades. Clean them if necessary.
6. Clean the tank.
Pumped fluids harmful to health. Dangerous for people and the environment!
➜ The pumping station used to discharge fluids harmful to health must be
decontaminated.
If necessary, wear a mask and protective clothing.

5. MAINTENANCE

Work carried out on the pumping station by unqualified staff. Risk of injury!
➜ Repairs and maintenance must be performed by specially trained staff
➜ Observe the safety and basic instructions.
Pumped fluids harmful to health. Dangerous for people and the environment!
➜ Pumping stations used to discharge fluids that may be harmful to health
must be decontaminated.
If necessary, wear a mask and protective clothing.
Work on the pumping station without adequate preparation.
Risk of injury!
➜ Properly stop the pumping station and secure it against inadvertent
operation.
➜ Close the inlet and discharge valves.
➜ Drain the sump in which the pumping station is installed.
➜ Allow the pumping station to cool to room temperature.
The pumping station must be maintained in such a way as to ensure proper discharge of wastewater
and to detect and eliminate malfunctions at an early stage. The proper functioning of the pumping
26
WARNING
WARNING
WARNING
WARNING