Control Panel - Parker PSE 325 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.4 Stop
a) Stop the compressor or the air fl ow through the dryer and wait 2
minutes before shutting down the dryer;
b) Close the inlet air valve to ensure compressed air does not enter the
dryer when disconnected or if an alarm occurs.
set
c) Press
to stop the dryer (for model 325-500).
Press
to stop the dryer (for model 700-1000).
&
d) Turn the MAIN SWITCH "
" to "O OFF" to switch power off.
Y
Wc version, close the water circuit with the dryer stopped.
5 Control
(PSE325-500)

5.1 Control panel

Fig.1
1
2
1
2
3
I
QS
O
QS Main power switch.
UP button: press to increase the value of a selected
editable parameter.
DOWN button: press to decrease the value of a selected
editable parameter.
esc
ESC button : to exit without saving/confi rming the values;
returns to the previous level;
PRESSED FOR 5s. ALARM RESET.
set
SET button : to exit and saving/confi rming the value;
go to the next level;
enter on Set Menu;
PRESSED FOR 5s. START DRYER.
esc
set
and
.
: press together at the same time to enter into the
parameter settings of the dryer.
English
5.2 Symbol
Symbol
Symbol status
Function
k
Lit up
Compressor ON
Off
Compressor OFF
Lit up
Dryer ON
Flashing
Dryer OFF
Lit up
Alarm present
!
Flashing
Warning present
Off
No alarm present
q
Lit up
Condensate drain ON
Off
Condensate drain OFF
5.3 Unit of measurement settings
How to set the temperature unit of measurement.
esc
set
Press
and
together at the same time to enter general menu
"PAr" .
set
to fi nd menu " CF9" .
Press
set
Press
to enter
to fi nd menu " CFJi".
Use the arrows
or
set
Press
to choose: ON : Fahrenheit / OFF: Celsius.
set
Press
to confi rm.
esc
Press
to exit.
esc
set
PAr
set
esc
CF9
set
esc
CFJi
---
set
esc
OFF
PSE 325-1000 60Hz
5.4 Confi guration condensate drain
There are three modes of operation:
a) CAPACITIVE = Automatic drainign using a capacitive sensor;
b) TIMED = programmable draining times;
c) CONTINUOUS (external) = if there is an external drain.
esc
set
Press
and
together at the same time to enter general
menu "PAr" .
set
Press
to enter.
Use the arrows
or
set
Press
to enter.
Use the arrows
or
set
Press
to choose the type of the drain:
0 = external;
1 = timed;
2 = capacitive.
set
Press
for fi ve seconds to select the drain.
esc
set
PAr
set
esc
CF9
d3
set
esc
0
For option (1) timed drain, users can set the ON/OFF time of the drain.
The following explains how:
On menu " Cd "
Use the arrows
or
ing time of the drain.
set
On
Press
to confi rm.
Use the arrows
or
ing time of the drain.
to fi nd menu " Cd "
to fi nd parameter " d3 "
........
Cd
set
esc
d2
d1
2
1
to fi nd parameter "d1" and set the open-
to fi nd parameter " d2 " and set the clos-
3/12

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Pse 400Pse 500Pse 700Pse 800Pse 1000

Table des Matières