8.2.4 – CLEANING THE CONDENSER
Carry out this operation every 60 days.
APPLIANCE STATUS:
-
ON/OFF button on OFF (
-
power supply plug disconnected from the mains.
AUTHORIZED PERSONNEL
Appliance operator.
METHOD
For trouble-free efficient appliance operation, the air-cooled condenser (ref. 1 fig. 9) must be kept clean so that air
circulates freely. Cleaning must be done once every 60 days at the most. Remove the panel by means of lower screws
(ref. 2, fig. 9). Use non-metallic brushes to clean, ensuring that all the dust and fluff is removed from the fins. We
recommend using a vacuum cleaner so as to avoid dust being dispersed into the environment. If there are greasy
deposits, remove them using a small brush soaked in alcohol. DO NOT SCRAPE THE SURFACES WITH SHARP
POINTED OR ABRASIVE OBJECTS.
The condenser has sharp edges. When carrying out the operations mentioned above, wear
safety gloves, goggles and face masks.
Do not use direct water jets to clean the appliance.