Specifications; Dimensions - Elkron EL50RT 2PH 60m Manuel D'installation

Barrières extérieures à infrarouge
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.0 SPECIFICATIONS

Detection distance:..............................................................................60 m (outdoor), 120 m (indoor)
Current Consumption: .........................................................................85 mA (max)
Selectable Beam Frequency ...............................................................4 channel
Power supply:......................................................................................10.5V - 30 VDC (non polarity)
Infrared photoelectric .........................................................................led pulsed beams, double modulation
Detection systems: .............................................................................Simultaneous breaking of 2 beams
Response time ...................................................................................50msec ~ 700msec ( Adjustable )
Alarm output: ......................................................................................Dry connect relay NC./ NO. 0.2A / 28VDC
Tamper output:....................................................................................Dry connect relay NC. 0.2A / 28VDC
Alarm LED: ..........................................................................................Red LED (Receiver) lights when an alarm
Attenuation LED: .................................................................................Yellow LED (Receiver) lights when beam
Functions:............................................................................................RF-Monitor Jack, Meter Monitor Jack
Alignment Angle: ................................................................................Horizontal ±90°, Vertical ±10°
Operating Temperature: ......................................................................-25° to +55°C
Installation: .........................................................................................Indoor / Outdoor
Wiring: ................................................................................................Terminals
Weight: ...............................................................................................924 gr (Tx and RX)
Dimensions: .......................................................................................76 x 181,5 x 77,8 mm (l x h x p)
Standard Accessories: .......................................................................U-Shaped brackets x 2

10.0 DIMENSIONS

is initiated.
is attenuated
output A.G.C. circuit, Frost proof cover.
Attenuation Sheet x 1
Screws ( 4x20 Self tapping ) x 4
Screws ( M4 x 20 ) x 4
18/28