6.0 BEAM FREQUENCY CHANGE

- Set Transmitter and Receiver at the same channel.
- Refer to the figures and set the beam channel when two or more units are installed in stacked protection or in
line protection.
- When stacked protection is set up, both the upper and lower sensors should be the same model number
types.
stacked protection
Line & 2-stacked protection

7.0 ALIGNMENT AND OPERATION

- Apply power to both Transmitter and Receiver.
- Looking through the view finder, locate the other detector in the center of the sights by adjusting vertically
and horizontally.
- Connect the volt-meter (DC10V) to monitor jack input on Receiver's (+) and (-).
- Fine adjust the optical alignment for Transmitter to obtain maximum voltage from the volt-meter.
- Fine adjust the optlcal alignment for Receiver to obtain maximum voltage from the volt-meter.
Line protection
Horizontal
Adjustment
15/28
Channel Set
DIP-SW.
View Finder
Vertical adjustment screw
Screw clockwiseGUpward
CounterclockwiseGDownward