3. VENTING REQUIREMENTS / HEIGHT & CLEARANCE
Vent system must terminate outside (roof or side wall).
DO NOT terminate the vent system in an attic or other
enclosed area.
DO NOT use 4 inches (10.2 cm) laundry-type wall caps.
Use metal/aluminum vent only. Rigid metal/ aluminum
vent is recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper airflow.
Calculate the following figures before installation:
1. Distance from the floor to the ceiling.
2. Distance between the floor to the countertop/stove -
28 to 31 inches (71 - 79 cm) is recommeded for
electric cooktops and 30 to
36 inches (76 - 91 cm) is recommended for gas
ranges.
3. Distance between the countertop/stove to the range
hood.
4. Height of hood and duct cover.
For the most efficient & quiet operation:
A distance of 228 to 31 inches (71 - 79 cm) is
recommeded for electric cooktops and 30 to
36 inches (76 - 91 cm) is recommended for gas
ranges.
It is recommended that the range hood be vented
vertically through the roof through 6 inches (15 cm) or
larger round metal/aluminum vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24 inches
(61 cm) of straight vent between the elbows if more
than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of elbows
should be kept to a minimum to provide efficient
performance.
The vent system must have a damper. If roof or wall cap
has a damper, DO NOT use damper (if supplied) on top
of the range hood.
Use silver tape or duct tape to seal all joints in the vent
system.
Use caulking to seal exterior wall or roof opening
around the cap.
5
Hood
Cooktop