CAME G4040EZ Manuel D'installation page 58

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PAIRED CONNECTION
 Important! First do the following on both operators:
- insert the RSE card (with the dipswitches set to OFF) on the panel connector on both operators.
- connect the two boards with a CAT 5 cable (max. 1,000 m) to terminals A-A / B-B / GND-GND; see CONNECTION FOR PAIRED OR ALTERNATE
OPERATION)
- connect all command and safety devices on the MASTER operator panel.
 Important! Deactivate the F 19 function (automatic closing time) on the panel on the SLAVE operator.
Saving
Follow the procedure for entering a user with the OPEN and PARTIAL/PEDESTRIAN OPENING command on the MASTER panel.
Confi guring the MASTER operator
MASTER
Select function F 49. Press ENTER to confi rm.
Select 1 (paired) and press ENTER.
Parameter transfer from MASTER to SLAVE
Select function F 52 on the MASTER panel.
Select 1 and press ENTER.
SLAVE
Programming
Set the following functions on both barriers:
- motor type (A1);
- motor test (A2);
- total stop (F1);
- travel calibration (A3).
Proceed with setting and adjusting the MASTER panel.
Function modes
 STEP-BY-STEP or OPEN command Both booms open.
 PARTIAL/PEDESTRIAN opening command. Only the boom on the MASTER barrier opens.
For information on the types of command that can be selected and associated with users, see the section ENTERING A USER WITH AN ASSOCIATED
COMMAND.
MASTER
MASTER
SLAVE
SLAVE

Publicité

Table des Matières
loading

Table des Matières